Tech Drive TD-BF-04 Exhaust Fan Specifications

ENERGY STAR PD #3477588 · Bathroom/Utility Room · Qualified 2024-05-03
Verified Specification Summary

In EPA dataset 8dv7-nngq, Tech Drive TD-BF-04 tests at 80 CFM free discharge (57.7 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 57 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-04 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 57.7 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
72.1% @ 0.25"
Motor Draw
18.6 W (6.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive TD-BF-04 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.7 CFM at 0.25 in. w.g. (72.1% retention, 15.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3477588 verifies TD-BF-04 (series: TD-BF) under Tech Drive (27 listed models, qualified 2024-05-03). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Air King AK80 (80.0 CFM) and Commercial Electric BPT13-14D (80.0 CFM).

Does Tech Drive TD-BF-04 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Tech Drive TD-BF-04 at 1.5 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why avoid unvented attic termination with Tech Drive TD-BF-04?

Under ASHRAE 62.2 best practice, Tech Drive TD-BF-04 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Tech Drive TD-BF-04?

Before cutting ceiling drywall or sizing attic transitions for Tech Drive TD-BF-04, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series TD-BF-04 / TD-BF PD ID 3477588 (Qualified 2024-05-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (57.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Tech Drive TD-BF-04?

Bathroom ventilation sizing below maps Tech Drive TD-BF-04 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-04
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 57 sq ft1 CFM/sq ft @ 57.7 CFM
Tall Bath (9-ft Ceiling)Up to 51 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.8 kWh/yr (~$1.09/yr)18.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2162.9 kWh/yr (~$26.06/yr)18.6 W x 8,760 hrs / 1,000

What peer models sit nearest Tech Drive TD-BF-04 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Tech Drive TD-BF-04.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK80 80 / 68.8 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14D 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT13-14HD 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Valu+ BPT13-14DT-2 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
VENTECHLATION BPT13-14DT-1 80 / 57.7 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter

What percentage of room demand does Tech Drive TD-BF-04 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Tech Drive TD-BF-04 tested delivery.

When does Tech Drive TD-BF-04 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tech Drive TD-BF-04.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 57.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 1.5 sones up to 57 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Tech Drive TD-BF-04?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Tech Drive TD-BF-04.

How much airflow does Tech Drive TD-BF-04 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Tech Drive TD-BF-04 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Tech Drive TD-BF-04 disturb adjacent bedrooms during night use?

Acoustic measurement places Tech Drive TD-BF-04 at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Tech Drive TD-BF-04 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Tech Drive TD-BF-04 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Tech Drive TD-BF-04 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-04's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive TD-BF-04?

Tech Drive TD-BF-04 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive TD-BF-04's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-04's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Tech Drive TD-BF-04 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-04 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Tech Drive TD-BF-04?

Do not force Tech Drive TD-BF-04 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.