In EPA dataset 8dv7-nngq, Delta VFB080B4A1-LVDC tests at 80 CFM free discharge (61.9 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 7.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 61 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VFB080B4A1-LVDC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 61.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 7.8 CFM/W (#365/1,145)
- Static Retention
- 77.4% @ 0.25"
- Motor Draw
- 10.3 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta VFB080B4A1-LVDC vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.9 CFM at 0.25 in. w.g. (77.4% retention, 10.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places VFB080B4A1-LVDC (series: BreezIntegrity) (PD #4667274) among 121 Delta entries qualified through 2026-07-08. Lighting kit: No. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.3 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 90.2 kWh/yr (~$14.43/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta 80F-LED (80.0 CFM).
Does Delta VFB080B4A1-LVDC fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta VFB080B4A1-LVDC at 1.5 sones.
Why avoid unvented attic termination with Delta VFB080B4A1-LVDC?
Under ASHRAE 62.2 best practice, Delta VFB080B4A1-LVDC needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta VFB080B4A1-LVDC?
Before cutting ceiling drywall or sizing attic transitions for Delta VFB080B4A1-LVDC, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VFB080B4A1-LVDC / BreezIntegrity | PD ID 4667274 (Qualified 2026-07-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (61.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta VFB080B4A1-LVDC?
Bathroom ventilation sizing below maps Delta VFB080B4A1-LVDC motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 90.2 kWh/yr (~$14.43/yr) | 10.3 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta VFB080B4A1-LVDC in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta VFB080B4A1-LVDC.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7142-70-L | 70 / 55.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 3 in. diameter |
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-MB | 80 / 62.9 CFM | 1.5 sones (Same) | 7.2 CFM/W | 4 in. diameter |
What percentage of room demand does Delta VFB080B4A1-LVDC cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta VFB080B4A1-LVDC tested delivery.
What plumbing or duct constraints rule out Delta VFB080B4A1-LVDC?
Compare where Delta VFB080B4A1-LVDC excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 61.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 1.5 sones up to 61 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Delta VFB080B4A1-LVDC?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta VFB080B4A1-LVDC.
Is Delta VFB080B4A1-LVDC energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta VFB080B4A1-LVDC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VFB080B4A1-LVDC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta VFB080B4A1-LVDC?
Delta VFB080B4A1-LVDC features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta VFB080B4A1-LVDC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VFB080B4A1-LVDC's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta VFB080B4A1-LVDC serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta VFB080B4A1-LVDC supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta VFB080B4A1-LVDC for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta VFB080B4A1-LVDC lacks adequate reserve.
How does Delta VFB080B4A1-LVDC handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta VFB080B4A1-LVDC yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta VFB080B4A1-LVDC quiet enough for a primary bedroom bathroom?
At 1.5 sones, Delta VFB080B4A1-LVDC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)