In EPA dataset 8dv7-nngq, Panasonic Eco Solutions RG-N110LHA tests at 110 CFM free discharge (92.1 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 6.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 92 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions RG-N110LHA Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 92.1 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 6.1 CFM/W (#448/1,145)
- Static Retention
- 83.7% @ 0.25"
- Motor Draw
- 18.0 W (6.6 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Panasonic Eco Solutions RG-N110LHA vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.1 CFM at 0.25 in. w.g. (83.7% retention, 4.0 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2669653 verifies RG-N110LHA (series: Whisper Renew) under Panasonic Eco Solutions (9 listed models, qualified 2023-07-21). Lighting kit: Yes. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.0 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 157.7 kWh/yr (~$25.23/yr) continuously. Closest competing matches include Tech Drive TD-BF-10 (110.0 CFM) and Tech Drive TD-BF-10-H (110.0 CFM).
Does Panasonic Eco Solutions RG-N110LHA fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Panasonic Eco Solutions RG-N110LHA at 1.5 sones.
Why avoid unvented attic termination with Panasonic Eco Solutions RG-N110LHA?
Under ASHRAE 62.2 best practice, Panasonic Eco Solutions RG-N110LHA needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Panasonic Eco Solutions RG-N110LHA?
Before cutting ceiling drywall or sizing attic transitions for Panasonic Eco Solutions RG-N110LHA, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic Eco Solutions (9 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-N110LHA / Whisper Renew | PD ID 2669653 (Qualified 2023-07-21) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Panasonic Eco Solutions RG-N110LHA?
Bathroom ventilation sizing below maps Panasonic Eco Solutions RG-N110LHA motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 157.7 kWh/yr (~$25.23/yr) | 18.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest Panasonic Eco Solutions RG-N110LHA in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic Eco Solutions RG-N110LHA.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TG-H | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| VENTECHLATION BPT14-24TGHS | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Utilitech 7115-01 | 100 / 95.4 CFM | 1.5 sones (Same) | 6.5 CFM/W | 4 in. diameter |
What percentage of room demand does Panasonic Eco Solutions RG-N110LHA cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic Eco Solutions RG-N110LHA tested delivery.
Does Panasonic Eco Solutions RG-N110LHA suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic Eco Solutions RG-N110LHA for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 92.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 1.5 sones up to 92 sq ft
- Best application: Paired with rigid galvanized 3 in. diameter transition
Where do official rules set limits for Panasonic Eco Solutions RG-N110LHA?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic Eco Solutions RG-N110LHA.
How many kWh per year does Panasonic Eco Solutions RG-N110LHA add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Panasonic Eco Solutions RG-N110LHA averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Panasonic Eco Solutions RG-N110LHA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions RG-N110LHA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic Eco Solutions RG-N110LHA?
Panasonic Eco Solutions RG-N110LHA features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic Eco Solutions RG-N110LHA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions RG-N110LHA's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Panasonic Eco Solutions RG-N110LHA pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic Eco Solutions RG-N110LHA easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Panasonic Eco Solutions RG-N110LHA in a bathroom remodel?
Avoid specifying Panasonic Eco Solutions RG-N110LHA in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Panasonic Eco Solutions RG-N110LHA airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic Eco Solutions RG-N110LHA achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Panasonic Eco Solutions RG-N110LHA occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., Panasonic Eco Solutions RG-N110LHA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)