In EPA dataset 8dv7-nngq, Tech Drive FA-BF-04-L(BN) tests at 110 CFM free discharge (92.9 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 92 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-04-L(BN) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 92.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 84.5% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive FA-BF-04-L(BN) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.9 CFM at 0.25 in. w.g. (84.5% retention, 3.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Tech Drive registers 27 certified models, with SKU FA-BF-04-L(BN) (series: FA) (PD #4701294) certified since 2026-09-02. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Broan 791LEDM (110.0 CFM) and Commercial Electric BPT14-24OD-H (110.0 CFM).
Does Tech Drive FA-BF-04-L(BN) fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Tech Drive FA-BF-04-L(BN) at 1.5 sones.
Why avoid unvented attic termination with Tech Drive FA-BF-04-L(BN)?
Under ASHRAE 62.2 best practice, Tech Drive FA-BF-04-L(BN) needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Tech Drive FA-BF-04-L(BN)?
Before cutting ceiling drywall or sizing attic transitions for Tech Drive FA-BF-04-L(BN), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FA-BF-04-L(BN) / FA | PD ID 4701294 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Tech Drive FA-BF-04-L(BN)?
Bathroom ventilation sizing below maps Tech Drive FA-BF-04-L(BN) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest Tech Drive FA-BF-04-L(BN) in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Tech Drive FA-BF-04-L(BN).
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Nutone 791LEDNTM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
What percentage of room demand does Tech Drive FA-BF-04-L(BN) cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Tech Drive FA-BF-04-L(BN) tested delivery.
When does Tech Drive FA-BF-04-L(BN) fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Tech Drive FA-BF-04-L(BN).
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 92.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.5 sones up to 92 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Tech Drive FA-BF-04-L(BN)?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Tech Drive FA-BF-04-L(BN).
Which bathroom layouts should pick a larger blower than Tech Drive FA-BF-04-L(BN)?
Do not force Tech Drive FA-BF-04-L(BN) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Tech Drive FA-BF-04-L(BN) retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Tech Drive FA-BF-04-L(BN) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Tech Drive FA-BF-04-L(BN) disturb adjacent bedrooms during night use?
Acoustic measurement places Tech Drive FA-BF-04-L(BN) at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Tech Drive FA-BF-04-L(BN) continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Tech Drive FA-BF-04-L(BN) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Tech Drive FA-BF-04-L(BN) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-04-L(BN)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive FA-BF-04-L(BN)?
Tech Drive FA-BF-04-L(BN) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive FA-BF-04-L(BN)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-04-L(BN)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Is Tech Drive FA-BF-04-L(BN) code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-04-L(BN) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)