Skip to main content
Grant Estimator

Broan 791LEDM Exhaust Fan Specifications

ENERGY STAR PD #2332671 · Bathroom/Utility Room · Qualified 2018-11-30
Verified Specification Summary

The Broan 791LEDM (INVENT) moves 110 CFM at 0.1 in. w.g. (93.4 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 93 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan 791LEDM Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 93.4 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
84.9% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan 791LEDM vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 93.4 CFM at 0.25 in. w.g. (84.9% retention, 2.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU 791LEDM (series: INVENT) (PD #2332671) certified since 2018-11-30. Lighting kit: Yes. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Commercial Electric BPT14-24OD-H (110.0 CFM) and Nutone 791LEDNTM (110.0 CFM).

Where does Broan 791LEDM sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter Broan 791LEDM static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan 791LEDM?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan 791LEDM alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series 791LEDM / INVENT PD ID 2332671 (Qualified 2018-11-30)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (93.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Broan 791LEDM ventilate safely?

Sizing outputs below convert Broan 791LEDM tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan 791LEDM
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 93 sq ft1 CFM/sq ft @ 93.4 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 43 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan 791LEDM closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric BPT14-24OD-H 110 / 98.1 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Nutone 791LEDNTM 110 / 93.4 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Nutone AER110SLW 110 / 89.5 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Nutone AERN110LTK 110 / 89.9 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Nutone AERN110LTW 110 / 89.9 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter

Will Broan 791LEDM clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan 791LEDM satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Broan 791LEDM fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan 791LEDM.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 93 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Broan 791LEDM?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan 791LEDM.

Will Broan 791LEDM disturb adjacent bedrooms during night use?

Acoustic measurement places Broan 791LEDM at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Broan 791LEDM continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan 791LEDM draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan 791LEDM pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan 791LEDM's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan 791LEDM?

Broan 791LEDM features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan 791LEDM's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan 791LEDM's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan 791LEDM code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan 791LEDM clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan 791LEDM?

Do not force Broan 791LEDM into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan 791LEDM retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan 791LEDM produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories