The Nutone AERN110LTK (DECORATIVE) moves 110 CFM at 0.1 in. w.g. (89.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.2 CFM/W efficacy, sizing bathrooms up to 89 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AERN110LTK Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 89.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 81.7% @ 0.25"
- Motor Draw
- 26.2 W (9.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nutone AERN110LTK vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.9 CFM at 0.25 in. w.g. (81.7% retention, 6.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Nutone registers 16 certified models, with SKU AERN110LTK (series: DECORATIVE) (PD #2339167) certified since 2019-04-19. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).
Where does Nutone AERN110LTK sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Nutone AERN110LTK static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Nutone AERN110LTK?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Nutone AERN110LTK alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nutone (16 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AERN110LTK / DECORATIVE | PD ID 2339167 (Qualified 2019-04-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Nutone AERN110LTK ventilate safely?
Sizing outputs below convert Nutone AERN110LTK tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.6 kWh/yr (~$1.54/yr) | 26.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 229.5 kWh/yr (~$36.72/yr) | 26.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Nutone AERN110LTK closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
Will Nutone AERN110LTK clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Nutone AERN110LTK satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Nutone AERN110LTK in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Nutone AERN110LTK for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 39 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 89 sq ft with 8-ft ceilings (79 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Nutone AERN110LTK?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Nutone AERN110LTK.
What electrical efficiency and runtime kWh define Nutone AERN110LTK?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Nutone AERN110LTK pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AERN110LTK's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nutone AERN110LTK?
Nutone AERN110LTK features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nutone AERN110LTK's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AERN110LTK's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Nutone AERN110LTK satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Nutone AERN110LTK clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Nutone AERN110LTK undersized or poorly matched for a bath renovation?
Skip Nutone AERN110LTK if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Nutone AERN110LTK CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Nutone AERN110LTK registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Nutone AERN110LTK sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, Nutone AERN110LTK produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)