Nutone AERN110LTW Exhaust Fan Specifications

ENERGY STAR PD #3478081 · Bathroom/Utility Room · Qualified 2024-04-12
Verified Specification Summary

Tested under HVI protocols, the Nutone AERN110LTW exhaust unit achieves 110 CFM at 0.1 in. w.g. (89.9 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 89 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AERN110LTW Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 89.9 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
81.7% @ 0.25"
Motor Draw
26.2 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Nutone AERN110LTW vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.9 CFM at 0.25 in. w.g. (81.7% retention, 6.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Nutone's 16-unit lineup, AERN110LTW (series: INVENT) carries PD #3478081 dating to 2024-04-12. Lighting kit: Yes. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Broan AER110LTMB (110.0 CFM) and Broan AER110LTW (110.0 CFM).

Where do Nutone AERN110LTW sones rank across EPA ENERGY STAR fans?

Comparing Nutone AERN110LTW (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

What attic duct routing preserves Nutone AERN110LTW CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Nutone AERN110LTW, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Nutone AERN110LTW measure up on airflow and noise ratings?

Each row below breaks down Nutone AERN110LTW certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Nutone (16 models) ENERGY STAR Certified Partner
Model Number & Series AERN110LTW / INVENT PD ID 3478081 (Qualified 2024-04-12)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (89.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Nutone AERN110LTW CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Nutone AERN110LTW
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 89 sq ft1 CFM/sq ft @ 89.9 CFM
Tall Bath (9-ft Ceiling)Up to 79 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 39 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2229.5 kWh/yr (~$36.72/yr)26.2 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Nutone AERN110LTW?

Compare Nutone AERN110LTW side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AER110LTMB 110 / 89.9 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Broan AER110LTW 110 / 89.9 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter
Broan 791LEDM 110 / 93.4 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Commercial Electric BPT14-24OD-H 110 / 98.1 CFM 1.5 sones (Same) 4.3 CFM/W 4 in. diameter
Broan AER110RGBL 110 / 97 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter

Can you size Nutone AERN110LTW for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Nutone AERN110LTW verified capacity.

Where should contractors skip Nutone AERN110LTW on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Nutone AERN110LTW carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 89.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 1.5 sones up to 89 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Nutone AERN110LTW?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Nutone AERN110LTW.

How does Nutone AERN110LTW score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Nutone AERN110LTW delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Nutone AERN110LTW?

Rule out Nutone AERN110LTW when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Nutone AERN110LTW capacity?

Because static drag at 0.25 in. w.g. lowers Nutone AERN110LTW from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Nutone AERN110LTW compared with a standard 3.0 sone builder fan?

Tested at 1.5 sones, Nutone AERN110LTW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Nutone AERN110LTW consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Nutone AERN110LTW draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Nutone AERN110LTW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AERN110LTW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Nutone AERN110LTW?

Nutone AERN110LTW features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Nutone AERN110LTW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AERN110LTW's safe coverage footprint from 50 sq ft to 44 sq ft.