Nutone AERN110RGBLC Exhaust Fan Specifications

ENERGY STAR PD #2340598 · Bathroom/Utility Room · Qualified 2019-05-31
Verified Specification Summary

The Nutone AERN110RGBLC (INVENT) moves 110 CFM at 0.1 in. w.g. (97.6 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.0 CFM/W efficacy, sizing bathrooms up to 97 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AERN110RGBLC Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 97.6 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
88.7% @ 0.25"
Motor Draw
27.5 W (10.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Nutone AERN110RGBLC vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.6 CFM out of 110 CFM (88.7% retention, 1.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places AERN110RGBLC (series: INVENT) (PD #2340598) among 16 Nutone entries qualified through 2019-05-31. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.5 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 240.9 kWh/yr (~$38.54/yr) continuously. Closest competing matches include Commercial Electric 7130-16-CE (110.0 CFM) and Broan AER110RGBL (110.0 CFM).

Where does Nutone AERN110RGBLC sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter Nutone AERN110RGBLC static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Nutone AERN110RGBLC?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Nutone AERN110RGBLC alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Nutone (16 models) ENERGY STAR Certified Partner
Model Number & Series AERN110RGBLC / INVENT PD ID 2340598 (Qualified 2019-05-31)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Nutone AERN110RGBLC ventilate safely?

Sizing outputs below convert Nutone AERN110RGBLC tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Nutone AERN110RGBLC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.6 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.0 kWh/yr (~$1.60/yr)27.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2240.9 kWh/yr (~$38.54/yr)27.5 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Nutone AERN110RGBLC closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric 7130-16-CE 110 / 103.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Broan AER110RGBL 110 / 97 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-07-plus 110 / 91.6 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-25L-5CCT(BL) 110 / 91.6 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Akicon AK15110N5-B 110 / 100.5 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter

Will Nutone AERN110RGBLC clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Nutone AERN110RGBLC satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Nutone AERN110RGBLC?

Match Nutone AERN110RGBLC directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Nutone AERN110RGBLC?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Nutone AERN110RGBLC.

Where does Nutone AERN110RGBLC run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nutone AERN110RGBLC.

What happens to Nutone AERN110RGBLC CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Nutone AERN110RGBLC moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Nutone AERN110RGBLC sit on acoustic comfort for senior homeowners?

Measuring 1.5 sones, Nutone AERN110RGBLC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Nutone AERN110RGBLC cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Nutone AERN110RGBLC 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Nutone AERN110RGBLC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AERN110RGBLC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Nutone AERN110RGBLC?

Nutone AERN110RGBLC features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Nutone AERN110RGBLC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AERN110RGBLC's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Nutone AERN110RGBLC ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nutone AERN110RGBLC covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.