The Commercial Electric 7130-16-CE (7130-16-CE) moves 110 CFM at 0.1 in. w.g. (103.8 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.0 CFM/W efficacy, sizing bathrooms up to 103 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric 7130-16-CE Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 103.8 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 94.4% @ 0.25"
- Motor Draw
- 27.5 W (10.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric 7130-16-CE vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 103.8 CFM out of 110 CFM (94.4% retention, 6.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Commercial Electric maintains 15 active ENERGY STAR blowers; 7130-16-CE (series: 7130-16-CE) (PD #3477946) gained qualification on 2024-05-03. Lighting kit: Yes. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.5 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 240.9 kWh/yr (~$38.54/yr) continuously. Closest competing matches include Nutone AERN110RGBL (110.0 CFM) and Nutone AERN110RGBLC (110.0 CFM).
Where does Commercial Electric 7130-16-CE sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Commercial Electric 7130-16-CE static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Commercial Electric 7130-16-CE?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Commercial Electric 7130-16-CE alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7130-16-CE / 7130-16-CE | PD ID 3477946 (Qualified 2024-05-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (103.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Commercial Electric 7130-16-CE ventilate safely?
Sizing outputs below convert Commercial Electric 7130-16-CE tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 103 sq ft | 1 CFM/sq ft @ 103.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 92 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 53 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.0 kWh/yr (~$1.60/yr) | 27.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 240.9 kWh/yr (~$38.54/yr) | 27.5 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Commercial Electric 7130-16-CE closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-07-plus | 110 / 91.6 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-25L-5CCT(BL) | 110 / 91.6 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
Will Commercial Electric 7130-16-CE clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Commercial Electric 7130-16-CE satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Commercial Electric 7130-16-CE in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Commercial Electric 7130-16-CE for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 53 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 103 sq ft with 8-ft ceilings (92 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Commercial Electric 7130-16-CE?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Commercial Electric 7130-16-CE.
Why check Commercial Electric 7130-16-CE CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Commercial Electric 7130-16-CE registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Commercial Electric 7130-16-CE sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, Commercial Electric 7130-16-CE produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Commercial Electric 7130-16-CE?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Commercial Electric 7130-16-CE pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric 7130-16-CE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric 7130-16-CE?
Commercial Electric 7130-16-CE features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric 7130-16-CE's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric 7130-16-CE's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Commercial Electric 7130-16-CE satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Commercial Electric 7130-16-CE clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Commercial Electric 7130-16-CE undersized or poorly matched for a bath renovation?
Skip Commercial Electric 7130-16-CE if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.