In EPA dataset 8dv7-nngq, Tech Drive TD-BF-25L-5CCT(BL) tests at 110 CFM free discharge (91.6 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 91 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-25L-5CCT(BL) Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 91.6 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 83.3% @ 0.25"
- Motor Draw
- 26.8 W (9.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive TD-BF-25L-5CCT(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91.6 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Tech Drive TD-BF-25L-5CCT(BL) (series: TD) under PD #4718094 (27 models registered, 2026-10-21). Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan AER110RGBL (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).
Does Tech Drive TD-BF-25L-5CCT(BL) fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Tech Drive TD-BF-25L-5CCT(BL) at 1.5 sones.
Why avoid unvented attic termination with Tech Drive TD-BF-25L-5CCT(BL)?
Under ASHRAE 62.2 best practice, Tech Drive TD-BF-25L-5CCT(BL) needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Tech Drive TD-BF-25L-5CCT(BL)?
Before cutting ceiling drywall or sizing attic transitions for Tech Drive TD-BF-25L-5CCT(BL), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-25L-5CCT(BL) / TD | PD ID 4718094 (Qualified 2026-10-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (91.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Tech Drive TD-BF-25L-5CCT(BL)?
Bathroom ventilation sizing below maps Tech Drive TD-BF-25L-5CCT(BL) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest Tech Drive TD-BF-25L-5CCT(BL) in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Tech Drive TD-BF-25L-5CCT(BL).
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Commercial Electric 7130-16-CE | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
What percentage of room demand does Tech Drive TD-BF-25L-5CCT(BL) cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Tech Drive TD-BF-25L-5CCT(BL) tested delivery.
Who should not install Tech Drive TD-BF-25L-5CCT(BL) in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive TD-BF-25L-5CCT(BL) for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 91.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 1.5 sones up to 91 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Tech Drive TD-BF-25L-5CCT(BL)?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Tech Drive TD-BF-25L-5CCT(BL).
What electrical efficiency and runtime kWh define Tech Drive TD-BF-25L-5CCT(BL)?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Tech Drive TD-BF-25L-5CCT(BL) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-25L-5CCT(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-25L-5CCT(BL)?
Tech Drive TD-BF-25L-5CCT(BL) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-25L-5CCT(BL)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-25L-5CCT(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive TD-BF-25L-5CCT(BL) satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-25L-5CCT(BL) clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Tech Drive TD-BF-25L-5CCT(BL) undersized or poorly matched for a bath renovation?
Skip Tech Drive TD-BF-25L-5CCT(BL) if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Tech Drive TD-BF-25L-5CCT(BL) CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive TD-BF-25L-5CCT(BL) registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Tech Drive TD-BF-25L-5CCT(BL) sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, Tech Drive TD-BF-25L-5CCT(BL) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)