Certified by EPA ENERGY STAR, VENTECHLATION BPT14-24TG-H delivers 110 CFM free-air (99 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 99 sq ft (8-ft height) or 88 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT14-24TG-H Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 99 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.8 CFM/W (#534/1,145)
- Static Retention
- 90.0% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VENTECHLATION BPT14-24TG-H vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside VENTECHLATION's 12-unit lineup, BPT14-24TG-H (series: BPT) carries PD #4480280 dating to 2025-07-25. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Tech Drive TD-BF-10 (110.0 CFM) and Tech Drive TD-BF-10-H (110.0 CFM).
How noisy is VENTECHLATION BPT14-24TG-H compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while VENTECHLATION BPT14-24TG-H measures 1.5 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect VENTECHLATION BPT14-24TG-H airflow?
Connecting VENTECHLATION BPT14-24TG-H through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify VENTECHLATION BPT14-24TG-H performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for VENTECHLATION BPT14-24TG-H lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT14-24TG-H / BPT | PD ID 4480280 (Qualified 2025-07-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit VENTECHLATION BPT14-24TG-H?
Calculated coverage metrics translate VENTECHLATION BPT14-24TG-H airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to VENTECHLATION BPT14-24TG-H?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-10 | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-10-H | 110 / 99 CFM | 1.5 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(BL) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(BN) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Tech Drive FA-BF-04-L(WH) | 110 / 92.9 CFM | 1.5 sones (Same) | 4.5 CFM/W | 4 in. diameter |
Does VENTECHLATION BPT14-24TG-H match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check VENTECHLATION BPT14-24TG-H percentage capacity without sending data.
Who should not install VENTECHLATION BPT14-24TG-H in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VENTECHLATION BPT14-24TG-H for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 49 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 99 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for VENTECHLATION BPT14-24TG-H?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around VENTECHLATION BPT14-24TG-H.
When is VENTECHLATION BPT14-24TG-H undersized or poorly matched for a bath renovation?
Skip VENTECHLATION BPT14-24TG-H if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check VENTECHLATION BPT14-24TG-H CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VENTECHLATION BPT14-24TG-H registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does VENTECHLATION BPT14-24TG-H sound output compare to noisy contractor-grade fans?
Rated at 1.5 sones, VENTECHLATION BPT14-24TG-H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define VENTECHLATION BPT14-24TG-H?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can VENTECHLATION BPT14-24TG-H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT14-24TG-H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT14-24TG-H?
VENTECHLATION BPT14-24TG-H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT14-24TG-H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT14-24TG-H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does VENTECHLATION BPT14-24TG-H satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT14-24TG-H clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)