Homeowners specifying Tech Drive FA-BF-04-L(BL) gain 110 CFM at 0.1 in. w.g. (92.9 CFM at 0.25 in. w.g.) where it registers #412 of 607 in quietness (1.5 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 92 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-04-L(BL) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 92.9 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 84.5% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive FA-BF-04-L(BL) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.9 CFM at 0.25 in. w.g. (84.5% retention, 3.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Tech Drive FA-BF-04-L(BL) (series: FA) under PD #4697674 (27 models registered, 2026-09-02). Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Broan 791LEDM (110.0 CFM) and Commercial Electric BPT14-24OD-H (110.0 CFM).
What acoustic percentile does Tech Drive FA-BF-04-L(BL) occupy among 1,145 bath blowers?
Inspect how Tech Drive FA-BF-04-L(BL) positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Tech Drive FA-BF-04-L(BL) best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Tech Drive FA-BF-04-L(BL) housings.
Where do Tech Drive FA-BF-04-L(BL) acoustic and static metrics stand?
Compare Tech Drive FA-BF-04-L(BL) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FA-BF-04-L(BL) / FA | PD ID 4697674 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Tech Drive FA-BF-04-L(BL) handle taller ceilings or walk-in tub steam?
Evaluate how Tech Drive FA-BF-04-L(BL) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Tech Drive FA-BF-04-L(BL)?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Commercial Electric BPT14-24OD-H | 110 / 98.1 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Nutone 791LEDNTM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
Is Tech Drive FA-BF-04-L(BL) sized right for your shower or tub room?
Check whether Tech Drive FA-BF-04-L(BL) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Tech Drive FA-BF-04-L(BL) suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive FA-BF-04-L(BL) for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 42 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 92.9 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Tech Drive FA-BF-04-L(BL)?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive FA-BF-04-L(BL).
Does Tech Drive FA-BF-04-L(BL) pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-04-L(BL) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Tech Drive FA-BF-04-L(BL) in a bathroom remodel?
Avoid specifying Tech Drive FA-BF-04-L(BL) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Tech Drive FA-BF-04-L(BL) airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive FA-BF-04-L(BL) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Tech Drive FA-BF-04-L(BL) occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., Tech Drive FA-BF-04-L(BL) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Tech Drive FA-BF-04-L(BL) add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Tech Drive FA-BF-04-L(BL) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Tech Drive FA-BF-04-L(BL) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-04-L(BL)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive FA-BF-04-L(BL)?
Tech Drive FA-BF-04-L(BL) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive FA-BF-04-L(BL)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-04-L(BL)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)