Tested under HVI protocols, the Commercial Electric BPT14-24OD-H exhaust unit achieves 110 CFM at 0.1 in. w.g. (98.1 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 98 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BPT14-24OD-H Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 98.1 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 89.2% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric BPT14-24OD-H vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 98.1 CFM out of 110 CFM (89.2% retention, 1.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Commercial Electric registers 15 certified models, with SKU BPT14-24OD-H (series: BPT14) (PD #3531077) certified since 2024-05-24. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Broan 791LEDM (110.0 CFM) and Nutone 791LEDNTM (110.0 CFM).
Where do Commercial Electric BPT14-24OD-H sones rank across EPA ENERGY STAR fans?
Comparing Commercial Electric BPT14-24OD-H (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Commercial Electric BPT14-24OD-H CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Commercial Electric BPT14-24OD-H, preventing premature peeling paint and mold growth.
How does Commercial Electric BPT14-24OD-H measure up on airflow and noise ratings?
Each row below breaks down Commercial Electric BPT14-24OD-H certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT14-24OD-H / BPT14 | PD ID 3531077 (Qualified 2024-05-24) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (98.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Commercial Electric BPT14-24OD-H CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 98 sq ft | 1 CFM/sq ft @ 98.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 87 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 48 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Commercial Electric BPT14-24OD-H?
Compare Commercial Electric BPT14-24OD-H side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan 791LEDM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Nutone 791LEDNTM | 110 / 93.4 CFM | 1.5 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Broan AER110LTW | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Nutone AER110SLW | 110 / 89.5 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
Can you size Commercial Electric BPT14-24OD-H for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Commercial Electric BPT14-24OD-H verified capacity.
Does Commercial Electric BPT14-24OD-H suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Commercial Electric BPT14-24OD-H for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 98.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 1.5 sones up to 98 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Commercial Electric BPT14-24OD-H?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Commercial Electric BPT14-24OD-H.
What acoustic sone tier does Commercial Electric BPT14-24OD-H occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., Commercial Electric BPT14-24OD-H produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Commercial Electric BPT14-24OD-H add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Commercial Electric BPT14-24OD-H averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Commercial Electric BPT14-24OD-H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BPT14-24OD-H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric BPT14-24OD-H?
Commercial Electric BPT14-24OD-H features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric BPT14-24OD-H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BPT14-24OD-H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Commercial Electric BPT14-24OD-H pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BPT14-24OD-H easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Commercial Electric BPT14-24OD-H in a bathroom remodel?
Avoid specifying Commercial Electric BPT14-24OD-H in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Commercial Electric BPT14-24OD-H airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Commercial Electric BPT14-24OD-H achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)