The Tech Drive TD-BF-07-plus (TD) moves 110 CFM at 0.1 in. w.g. (91.6 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.1 CFM/W efficacy, sizing bathrooms up to 91 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-07-plus Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 91.6 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 83.3% @ 0.25"
- Motor Draw
- 26.8 W (9.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Tech Drive TD-BF-07-plus vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91.6 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Tech Drive registers 27 certified models, with SKU TD-BF-07-plus (series: TD) (PD #4697534) certified since 2026-09-02. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan AER110RGBL (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).
Where does Tech Drive TD-BF-07-plus sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.
How does duct geometry alter Tech Drive TD-BF-07-plus static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Tech Drive TD-BF-07-plus?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive TD-BF-07-plus alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-07-plus / TD | PD ID 4697534 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (91.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Tech Drive TD-BF-07-plus ventilate safely?
Sizing outputs below convert Tech Drive TD-BF-07-plus tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 81 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.8 kWh/yr (~$1.57/yr) | 26.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 234.8 kWh/yr (~$37.57/yr) | 26.8 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Tech Drive TD-BF-07-plus closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Commercial Electric 7130-16-CE | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan AER110LTMB | 110 / 89.9 CFM | 1.5 sones (Same) | 4.2 CFM/W | 4 in. diameter |
Will Tech Drive TD-BF-07-plus clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Tech Drive TD-BF-07-plus satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Tech Drive TD-BF-07-plus suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-07-plus for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 41 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 91 sq ft with 8-ft ceilings (81 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Tech Drive TD-BF-07-plus?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive TD-BF-07-plus.
What acoustic sone tier does Tech Drive TD-BF-07-plus occupy in EPA filings?
With 1.5 sones at 0.1 in. w.g., Tech Drive TD-BF-07-plus produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Tech Drive TD-BF-07-plus add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-07-plus averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Tech Drive TD-BF-07-plus pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-07-plus's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-07-plus?
Tech Drive TD-BF-07-plus features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-07-plus's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-07-plus's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive TD-BF-07-plus pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-07-plus easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Tech Drive TD-BF-07-plus in a bathroom remodel?
Avoid specifying Tech Drive TD-BF-07-plus in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Tech Drive TD-BF-07-plus airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-07-plus achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)