The Tech Drive TD-BF-07-plus (TD) moves 110 CFM at 0.1 in. w.g. (91.6 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones), and delivers 4.1 CFM/W efficacy, sizing bathrooms up to 91 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-07-plus Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 91.6 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
83.3% @ 0.25"
Motor Draw
26.8 W (9.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive TD-BF-07-plus vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91.6 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Tech Drive registers 27 certified models, with SKU TD-BF-07-plus (series: TD) (PD #4697534) certified since 2026-09-02. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.8 watts, about 9.8 kWh/yr (~$1.57/yr at $0.16/kWh) for 1 hr/day shower timers or 234.8 kWh/yr (~$37.57/yr) continuously. Closest competing matches include Broan AER110RGBL (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).

Where does Tech Drive TD-BF-07-plus sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

How does duct geometry alter Tech Drive TD-BF-07-plus static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Tech Drive TD-BF-07-plus?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive TD-BF-07-plus alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series TD-BF-07-plus / TD PD ID 4697534 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (91.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Tech Drive TD-BF-07-plus ventilate safely?

Sizing outputs below convert Tech Drive TD-BF-07-plus tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-07-plus
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 91 sq ft1 CFM/sq ft @ 91.6 CFM
Tall Bath (9-ft Ceiling)Up to 81 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 41 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.8 kWh/yr (~$1.57/yr)26.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2234.8 kWh/yr (~$37.57/yr)26.8 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Tech Drive TD-BF-07-plus closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AER110RGBL 110 / 97 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter
Commercial Electric 7130-16-CE 110 / 103.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Nutone AERN110RGBL 110 / 97.6 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Nutone AERN110RGBLC 110 / 97.6 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Broan AER110LTMB 110 / 89.9 CFM 1.5 sones (Same) 4.2 CFM/W 4 in. diameter

Will Tech Drive TD-BF-07-plus clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Tech Drive TD-BF-07-plus satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Does Tech Drive TD-BF-07-plus suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-07-plus for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 41 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 91 sq ft with 8-ft ceilings (81 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Tech Drive TD-BF-07-plus?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive TD-BF-07-plus.

What acoustic sone tier does Tech Drive TD-BF-07-plus occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Tech Drive TD-BF-07-plus produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Tech Drive TD-BF-07-plus add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-07-plus averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Tech Drive TD-BF-07-plus pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-07-plus's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive TD-BF-07-plus?

Tech Drive TD-BF-07-plus features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive TD-BF-07-plus's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-07-plus's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Tech Drive TD-BF-07-plus pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-07-plus easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Tech Drive TD-BF-07-plus in a bathroom remodel?

Avoid specifying Tech Drive TD-BF-07-plus in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Tech Drive TD-BF-07-plus airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-07-plus achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)