Tested under HVI protocols, the Akicon AK15110N5-B exhaust unit achieves 110 CFM at 0.1 in. w.g. (100.5 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 100 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK15110N5-B Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 100.5 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 91.4% @ 0.25"
- Motor Draw
- 28.2 W (10.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK15110N5-B vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.5 CFM out of 110 CFM (91.4% retention, 3.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Akicon's 14-unit lineup, AK15110N5-B (series: AK15110N5-B) carries PD #4592474 dating to 2026-03-25. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Commercial Electric 7130-20-CE (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).
Where do Akicon AK15110N5-B sones rank across EPA ENERGY STAR fans?
Comparing Akicon AK15110N5-B (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Akicon AK15110N5-B CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Akicon AK15110N5-B, preventing premature peeling paint and mold growth.
How does Akicon AK15110N5-B measure up on airflow and noise ratings?
Each row below breaks down Akicon AK15110N5-B certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK15110N5-B / AK15110N5-B | PD ID 4592474 (Qualified 2026-03-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Akicon AK15110N5-B CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Akicon AK15110N5-B?
Compare Akicon AK15110N5-B side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric 7130-20-CE | 110 / 98.4 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Commercial Electric 7130-16-CE | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
Can you size Akicon AK15110N5-B for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Akicon AK15110N5-B verified capacity.
Where should contractors skip Akicon AK15110N5-B on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Akicon AK15110N5-B carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 100.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 1.5 sones up to 100 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Akicon AK15110N5-B?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Akicon AK15110N5-B.
What duct and room conditions disqualify Akicon AK15110N5-B?
Rule out Akicon AK15110N5-B when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Akicon AK15110N5-B capacity?
Because static drag at 0.25 in. w.g. lowers Akicon AK15110N5-B from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Akicon AK15110N5-B compared with a standard 3.0 sone builder fan?
Tested at 1.5 sones, Akicon AK15110N5-B produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Akicon AK15110N5-B consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Akicon AK15110N5-B draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Akicon AK15110N5-B pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK15110N5-B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK15110N5-B?
Akicon AK15110N5-B features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK15110N5-B's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK15110N5-B's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Akicon AK15110N5-B score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Akicon AK15110N5-B delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)