Rated for 110 CFM open-air (100.5 CFM at 0.25 in. w.g.), Akicon AK15110N5-W registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 100 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK15110N5-W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 100.5 CFM
- Noise @ 0.1"
- 1.5 sones (#412/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 91.4% @ 0.25"
- Motor Draw
- 28.2 W (10.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK15110N5-W vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.5 CFM out of 110 CFM (91.4% retention, 3.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Akicon AK15110N5-W (series: AK15110N5-W) under PD #4592514 (14 models registered, 2026-03-25). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Commercial Electric 7130-20-CE (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).
How does Akicon AK15110N5-W acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Akicon AK15110N5-W (1.5 sones).
How do flex elbows choke Akicon AK15110N5-W at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Akicon AK15110N5-W moving full rated CFM.
Does Akicon AK15110N5-W meet residential exhaust fan code specs?
Inspect Akicon AK15110N5-W mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK15110N5-W / AK15110N5-W | PD ID 4592514 (Qualified 2026-03-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Akicon AK15110N5-W airflow output?
Annual electricity figures and room square-footage ceilings below reflect Akicon AK15110N5-W tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 89 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.3 kWh/yr (~$1.65/yr) | 28.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 247.0 kWh/yr (~$39.52/yr) | 28.2 W x 8,760 hrs / 1,000 |
Which competing models share Akicon AK15110N5-W airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric 7130-20-CE | 110 / 98.4 CFM | 1.5 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Commercial Electric 7130-16-CE | 110 / 103.8 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBL | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Nutone AERN110RGBLC | 110 / 97.6 CFM | 1.5 sones (Same) | 4.0 CFM/W | 4 in. diameter |
| Broan AER110RGBL | 110 / 97 CFM | 1.5 sones (Same) | 4.1 CFM/W | 4 in. diameter |
How much airflow margin does Akicon AK15110N5-W give your bath?
Run a quick local room-volume check for Akicon AK15110N5-W by entering square footage and ceiling height to spot under-vented steam risks early.
When does Akicon AK15110N5-W fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Akicon AK15110N5-W.
Limitations & Who Should Skip
- Steam or walk-in tub room > 50 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 100 sq ft with 8-ft ceilings (89 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Akicon AK15110N5-W?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Akicon AK15110N5-W.
Does running Akicon AK15110N5-W continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Akicon AK15110N5-W draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Akicon AK15110N5-W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK15110N5-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK15110N5-W?
Akicon AK15110N5-W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK15110N5-W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK15110N5-W's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Akicon AK15110N5-W code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Akicon AK15110N5-W clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Akicon AK15110N5-W?
Do not force Akicon AK15110N5-W into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Akicon AK15110N5-W retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Akicon AK15110N5-W produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Akicon AK15110N5-W disturb adjacent bedrooms during night use?
Acoustic measurement places Akicon AK15110N5-W at 1.5 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)