Akicon AK15110N5-S Exhaust Fan Specifications

ENERGY STAR PD #4592494 · Bathroom/Utility Room · Qualified 2026-03-25
Verified Specification Summary

In EPA dataset 8dv7-nngq, Akicon AK15110N5-S tests at 110 CFM free discharge (100.5 CFM at 0.25 in. w.g.) and registers #412 of 607 in quietness (1.5 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 100 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK15110N5-S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 100.5 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
91.4% @ 0.25"
Motor Draw
28.2 W (10.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK15110N5-S vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.5 CFM out of 110 CFM (91.4% retention, 3.7 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4592494 verifies AK15110N5-S (series: AK15110N5-S) under Akicon (14 listed models, qualified 2026-03-25). Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Commercial Electric 7130-20-CE (110.0 CFM) and Commercial Electric 7130-16-CE (110.0 CFM).

Does Akicon AK15110N5-S fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Akicon AK15110N5-S at 1.5 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

Why avoid unvented attic termination with Akicon AK15110N5-S?

Under ASHRAE 62.2 best practice, Akicon AK15110N5-S needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Akicon AK15110N5-S?

Before cutting ceiling drywall or sizing attic transitions for Akicon AK15110N5-S, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK15110N5-S / AK15110N5-S PD ID 4592494 (Qualified 2026-03-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Akicon AK15110N5-S?

Bathroom ventilation sizing below maps Akicon AK15110N5-S motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Akicon AK15110N5-S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100.5 CFM
Tall Bath (9-ft Ceiling)Up to 89 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.3 kWh/yr (~$1.65/yr)28.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2247.0 kWh/yr (~$39.52/yr)28.2 W x 8,760 hrs / 1,000

What peer models sit nearest Akicon AK15110N5-S in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Akicon AK15110N5-S.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric 7130-20-CE 110 / 98.4 CFM 1.5 sones (Same) 3.9 CFM/W 4 in. diameter
Commercial Electric 7130-16-CE 110 / 103.8 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Nutone AERN110RGBL 110 / 97.6 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Nutone AERN110RGBLC 110 / 97.6 CFM 1.5 sones (Same) 4.0 CFM/W 4 in. diameter
Broan AER110RGBL 110 / 97 CFM 1.5 sones (Same) 4.1 CFM/W 4 in. diameter

What percentage of room demand does Akicon AK15110N5-S cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Akicon AK15110N5-S tested delivery.

Does Akicon AK15110N5-S suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Akicon AK15110N5-S for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 100.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 1.5 sones up to 100 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Akicon AK15110N5-S?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Akicon AK15110N5-S.

What acoustic sone tier does Akicon AK15110N5-S occupy in EPA filings?

With 1.5 sones at 0.1 in. w.g., Akicon AK15110N5-S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Akicon AK15110N5-S add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Akicon AK15110N5-S averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Akicon AK15110N5-S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK15110N5-S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK15110N5-S?

Akicon AK15110N5-S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK15110N5-S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK15110N5-S's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Akicon AK15110N5-S pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Akicon AK15110N5-S easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Akicon AK15110N5-S in a bathroom remodel?

Avoid specifying Akicon AK15110N5-S in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Akicon AK15110N5-S airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Akicon AK15110N5-S achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)