Tested under HVI protocols, the Delta VFB25AEH exhaust unit achieves 130 CFM at 0.1 in. w.g. (108.1 CFM at 0.25 in. w.g.), registers #522 of 607 in quietness (2.0 sones) and delivers 6.7 CFM/W efficacy, covering standard baths up to 108 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta VFB25AEH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / 108.1 CFM
- Noise @ 0.1"
- 2.0 sones (#522/607)
- Efficacy Rank
- 6.7 CFM/W (#431/1,145)
- Static Retention
- 83.2% @ 0.25"
- Motor Draw
- 19.4 W (7.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta VFB25AEH vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 2.0 sones (#522 of 607 rated models, 1.00 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 130 CFM open-air to 108.1 CFM at 0.25 in. w.g. (83.2% retention, 4.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Delta VFB25AEH (series: BreezSignature) under PD #2254281 (121 models registered, 2015-12-01). Lighting kit: No. At 6.7 CFM/W (#431 of 1,145, top 37.7% of 1,145 rated models, more efficient than 62.3% of rated models, 2.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 19.4 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 169.9 kWh/yr (~$27.18/yr) continuously. Closest competing matches include Fantech FR 125 (411332) (130.0 CFM) and Fantech Rn 1 (89051) (130.0 CFM).
Where do Delta VFB25AEH sones rank across EPA ENERGY STAR fans?
Comparing Delta VFB25AEH (2.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Delta VFB25AEH CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta VFB25AEH, preventing premature peeling paint and mold growth.
How does Delta VFB25AEH measure up on airflow and noise ratings?
Each row below breaks down Delta VFB25AEH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VFB25AEH / BreezSignature | PD ID 2254281 (Qualified 2015-12-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (108.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (2.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Delta VFB25AEH CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.1 kWh/yr (~$1.14/yr) | 19.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 169.9 kWh/yr (~$27.18/yr) | 19.4 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta VFB25AEH?
Compare Delta VFB25AEH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Fantech FR 125 (411332) | 130 / N/A CFM | Unpublished | 7.0 CFM/W | 5 in. diameter |
| Fantech Rn 1 (89051) | 130 / N/A CFM | Unpublished | 7.3 CFM/W | 5 in. diameter |
| Fantech Rn1-C (606281) | 130 / N/A CFM | Unpublished | 7.3 CFM/W | 5 in. diameter |
| Panasonic FV-13NLFS1 | 130 / N/A CFM | Unpublished | 7.5 CFM/W | 6 in. diameter |
| Panasonic FV-13NLFSC1 | 130 / N/A CFM | Unpublished | 7.5 CFM/W | 6 in. diameter |
Can you size Delta VFB25AEH for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta VFB25AEH verified capacity.
What plumbing or duct constraints rule out Delta VFB25AEH?
Compare where Delta VFB25AEH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 108.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 2.0 sones up to 108 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Delta VFB25AEH?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta VFB25AEH.
Can Delta VFB25AEH serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta VFB25AEH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta VFB25AEH for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta VFB25AEH lacks adequate reserve.
How does Delta VFB25AEH handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta VFB25AEH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta VFB25AEH quiet enough for a primary bedroom bathroom?
At 2.0 sones, Delta VFB25AEH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta VFB25AEH energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta VFB25AEH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta VFB25AEH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta VFB25AEH?
Delta VFB25AEH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta VFB25AEH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta VFB25AEH's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)