Skip to main content
Grant Estimator

Panasonic FV-13NLFSC1 Exhaust Fan Specifications

ENERGY STAR PD #4687994 · In-line (single-port) · Qualified 2026-07-08
Verified Specification Summary

In EPA dataset 8dv7-nngq, Panasonic FV-13NLFSC1 tests at 130 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 130 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-13NLFSC1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.5 CFM/W (#390/1,145)
Static Retention
0.1" test only
Motor Draw
17.3 W (6.3 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-13NLFSC1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-13NLFSC1 (EPA filing PD #4687994) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Panasonic maintains 92 active ENERGY STAR blowers; FV-13NLFSC1 (series: WhisperFresh Plus) (PD #4687994) gained qualification on 2026-07-08. Lighting kit: No. At 7.5 CFM/W (#390 of 1,145, top 34.1% of 1,145 rated models, more efficient than 65.9% of rated models, 2.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.3 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 151.5 kWh/yr (~$24.24/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

Why avoid unvented attic termination with Panasonic FV-13NLFSC1?

Under ASHRAE 62.2 best practice, Panasonic FV-13NLFSC1 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Panasonic FV-13NLFSC1?

Before cutting ceiling drywall or sizing attic transitions for Panasonic FV-13NLFSC1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-13NLFSC1 / WhisperFresh Plus PD ID 4687994 (Qualified 2026-07-08)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (130 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Panasonic FV-13NLFSC1?

Bathroom ventilation sizing below maps Panasonic FV-13NLFSC1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Panasonic FV-13NLFSC1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 130 sq ft1 CFM/sq ft @ 130 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 80 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2151.5 kWh/yr (~$24.24/yr)17.3 W x 8,760 hrs / 1,000

What peer models sit nearest Panasonic FV-13NLFSC1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Panasonic FV-13NLFSC1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

What percentage of room demand does Panasonic FV-13NLFSC1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Panasonic FV-13NLFSC1 tested delivery.

Which bath layouts should avoid specifying Panasonic FV-13NLFSC1?

Match Panasonic FV-13NLFSC1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 130 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 130 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Panasonic FV-13NLFSC1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Panasonic FV-13NLFSC1.

What does Panasonic FV-13NLFSC1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-13NLFSC1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic FV-13NLFSC1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-13NLFSC1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-13NLFSC1?

Panasonic FV-13NLFSC1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-13NLFSC1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-13NLFSC1's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic FV-13NLFSC1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-13NLFSC1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Panasonic FV-13NLFSC1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-13NLFSC1.

What happens to Panasonic FV-13NLFSC1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-13NLFSC1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Panasonic FV-13NLFSC1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-13NLFSC1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories