Skip to main content
Grant Estimator

Panasonic FV-13NLFS1 Exhaust Fan Specifications

ENERGY STAR PD #4687954 · In-line (single-port) · Qualified 2026-07-08
Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-13NLFS1 delivers 130 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 130 sq ft (8-ft height) or 115 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-13NLFS1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
130 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.5 CFM/W (#390/1,145)
Static Retention
0.1" test only
Motor Draw
17.3 W (6.3 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-13NLFS1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-13NLFS1 (EPA filing PD #4687954) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Panasonic FV-13NLFS1 (series: WhisperFresh) under PD #4687954 (92 models registered, 2026-07-08). Lighting kit: No. At 7.5 CFM/W (#390 of 1,145, top 34.1% of 1,145 rated models, more efficient than 65.9% of rated models, 2.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.3 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 151.5 kWh/yr (~$24.24/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).

Why does rigid 6 in. diameter ducting protect Panasonic FV-13NLFS1 airflow?

Connecting Panasonic FV-13NLFS1 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Panasonic FV-13NLFS1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-13NLFS1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-13NLFS1 / WhisperFresh PD ID 4687954 (Qualified 2026-07-08)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (130 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Panasonic FV-13NLFS1?

Calculated coverage metrics translate Panasonic FV-13NLFS1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-13NLFS1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 130 sq ft1 CFM/sq ft @ 130 CFM
Tall Bath (9-ft Ceiling)Up to 115 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 80 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.3 kWh/yr (~$1.01/yr)17.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2151.5 kWh/yr (~$24.24/yr)17.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Panasonic FV-13NLFS1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter

Does Panasonic FV-13NLFS1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-13NLFS1 percentage capacity without sending data.

Who should not install Panasonic FV-13NLFS1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV-13NLFS1 for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 80 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 130 CFM net static output
  • Primary match: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Panasonic FV-13NLFS1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-13NLFS1.

What electrical efficiency and runtime kWh define Panasonic FV-13NLFS1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Panasonic FV-13NLFS1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-13NLFS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-13NLFS1?

Panasonic FV-13NLFS1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-13NLFS1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-13NLFS1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Panasonic FV-13NLFS1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-13NLFS1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Panasonic FV-13NLFS1 undersized or poorly matched for a bath renovation?

Skip Panasonic FV-13NLFS1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Panasonic FV-13NLFS1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV-13NLFS1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Panasonic FV-13NLFS1 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Panasonic FV-13NLFS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories