Certified by EPA ENERGY STAR, Panasonic FV-13NLFS1 delivers 130 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 130 sq ft (8-ft height) or 115 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-13NLFS1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 130 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.5 CFM/W (#390/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 17.3 W (6.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Most Eff.

What does Panasonic FV-13NLFS1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-13NLFS1 (EPA filing PD #4687954) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 130 CFM (#230 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Panasonic FV-13NLFS1 (series: WhisperFresh) under PD #4687954 (92 models registered, 2026-07-08). Lighting kit: No. At 7.5 CFM/W (#390 of 1,145, top 34.1% of 1,145 rated models, more efficient than 65.9% of rated models, 2.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.3 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 151.5 kWh/yr (~$24.24/yr) continuously. Closest competing matches include Broan QT130E (130.0 CFM) and Broan QT130LE (130.0 CFM).
Why does rigid 6 in. diameter ducting protect Panasonic FV-13NLFS1 airflow?
Connecting Panasonic FV-13NLFS1 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Panasonic FV-13NLFS1 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-13NLFS1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-13NLFS1 / WhisperFresh | PD ID 4687954 (Qualified 2026-07-08) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (130 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Panasonic FV-13NLFS1?
Calculated coverage metrics translate Panasonic FV-13NLFS1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 130 sq ft | 1 CFM/sq ft @ 130 CFM |
| Tall Bath (9-ft Ceiling) | Up to 115 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 80 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 151.5 kWh/yr (~$24.24/yr) | 17.3 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Panasonic FV-13NLFS1?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT130E | 130 / 130.4 CFM | 1.5 sones | 4.7 CFM/W | 6 in. diameter |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
Does Panasonic FV-13NLFS1 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-13NLFS1 percentage capacity without sending data.
Who should not install Panasonic FV-13NLFS1 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Panasonic FV-13NLFS1 for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 80 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 130 CFM net static output
- Primary match: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Panasonic FV-13NLFS1?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-13NLFS1.
What electrical efficiency and runtime kWh define Panasonic FV-13NLFS1?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Panasonic FV-13NLFS1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-13NLFS1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-13NLFS1?
Panasonic FV-13NLFS1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-13NLFS1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-13NLFS1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Panasonic FV-13NLFS1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-13NLFS1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Panasonic FV-13NLFS1 undersized or poorly matched for a bath renovation?
Skip Panasonic FV-13NLFS1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Panasonic FV-13NLFS1 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Panasonic FV-13NLFS1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Panasonic FV-13NLFS1 sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Panasonic FV-13NLFS1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)