In EPA dataset 8dv7-nngq, Utilitech UTLDS110 tests at 110 CFM free discharge (113.4 CFM at 0.25 in. w.g.) and registers #405 of 607 in quietness (1.4 sones) and delivers 8.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 113 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTLDS110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 113.4 CFM
Noise @ 0.1"
1.4 sones (#405/607)
Efficacy Rank
8.9 CFM/W (#300/1,145)
Static Retention
103.1% @ 0.25"
Motor Draw
12.4 W (4.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech UTLDS110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.4 sones (#405 of 607 rated models, 0.40 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 113.4 CFM out of 110 CFM (103.1% retention, 15.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Utilitech maintains 22 active ENERGY STAR blowers; UTLDS110 (series: Utilitech) (PD #4675034) gained qualification on 2026-07-08. Lighting kit: No. At 8.9 CFM/W (#300 of 1,145, top 26.6% of 1,145 rated models, more efficient than 73.4% of rated models, 4.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.4 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 108.6 kWh/yr (~$17.38/yr) continuously. Closest competing matches include Delta 100HS (100.0 CFM) and Delta GBR100LED-DECOR (100.0 CFM).

Does Utilitech UTLDS110 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Utilitech UTLDS110 at 1.4 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.4 sone: 1.4 sones (68th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.4 sone: 1.4 sones (P68)

Why avoid unvented attic termination with Utilitech UTLDS110?

Under ASHRAE 62.2 best practice, Utilitech UTLDS110 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Utilitech UTLDS110?

Before cutting ceiling drywall or sizing attic transitions for Utilitech UTLDS110, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series UTLDS110 / Utilitech PD ID 4675034 (Qualified 2026-07-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (113.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Utilitech UTLDS110?

Bathroom ventilation sizing below maps Utilitech UTLDS110 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Utilitech UTLDS110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 113 sq ft1 CFM/sq ft @ 113.4 CFM
Tall Bath (9-ft Ceiling)Up to 100 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 63 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.5 kWh/yr (~$0.72/yr)12.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2108.6 kWh/yr (~$17.38/yr)12.4 W x 8,760 hrs / 1,000

What peer models sit nearest Utilitech UTLDS110 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Utilitech UTLDS110.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta 100HS 100 / 84.1 CFM 1.4 sones (Same) 8.1 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones (+0.10) 8.4 CFM/W 4 in. diameter
Delta 100F 100 / 81.4 CFM 1.4 sones (Same) 7.9 CFM/W 4 in. diameter
Delta GBR100 100 / 81.4 CFM 1.4 sones (Same) 7.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones (+0.10) 7.8 CFM/W 4 in. diameter

What percentage of room demand does Utilitech UTLDS110 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Utilitech UTLDS110 tested delivery.

Who should not install Utilitech UTLDS110 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Utilitech UTLDS110 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 113.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.4 sones up to 113 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Utilitech UTLDS110?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Utilitech UTLDS110.

How does Utilitech UTLDS110 sound output compare to noisy contractor-grade fans?

Rated at 1.4 sones, Utilitech UTLDS110 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Utilitech UTLDS110?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Utilitech UTLDS110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTLDS110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech UTLDS110?

Utilitech UTLDS110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech UTLDS110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTLDS110's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Utilitech UTLDS110 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Utilitech UTLDS110 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Utilitech UTLDS110 undersized or poorly matched for a bath renovation?

Skip Utilitech UTLDS110 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Utilitech UTLDS110 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Utilitech UTLDS110 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories