Delta GBR100LED-DECOR Exhaust Fan Specifications

ENERGY STAR PD #2343237 · Bathroom/Utility Room · Qualified 2016-05-04
Verified Specification Summary

Tested under HVI protocols, the Delta GBR100LED-DECOR exhaust unit achieves 100 CFM at 0.1 in. w.g. (75 CFM at 0.25 in. w.g.), registers #412 of 607 in quietness (1.5 sones) and delivers 8.4 CFM/W efficacy, covering standard baths up to 75 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta GBR100LED-DECOR Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 75 CFM
Noise @ 0.1"
1.5 sones (#412/607)
Efficacy Rank
8.4 CFM/W (#317/1,145)
Static Retention
75.0% @ 0.25"
Motor Draw
11.9 W (4.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta GBR100LED-DECOR vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.5 sones (#412 of 607 rated models, 0.50 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 75 CFM at 0.25 in. w.g. (75.0% retention, 12.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Delta's 121-unit lineup, GBR100LED-DECOR (series: BreezGreenBuilder) carries PD #2343237 dating to 2016-05-04. Lighting kit: Yes. At 8.4 CFM/W (#317 of 1,145, top 27.9% of 1,145 rated models, more efficient than 72.1% of rated models, 3.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.9 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 104.2 kWh/yr (~$16.67/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

Where do Delta GBR100LED-DECOR sones rank across EPA ENERGY STAR fans?

Comparing Delta GBR100LED-DECOR (1.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.5 sone: 1.5 sones (85th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.5 sone: 1.5 sones (P85)

What attic duct routing preserves Delta GBR100LED-DECOR CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Delta GBR100LED-DECOR, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta GBR100LED-DECOR measure up on airflow and noise ratings?

Each row below breaks down Delta GBR100LED-DECOR certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series GBR100LED-DECOR / BreezGreenBuilder PD ID 2343237 (Qualified 2016-05-04)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (75 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.5 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Delta GBR100LED-DECOR CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta GBR100LED-DECOR
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 75 sq ft1 CFM/sq ft @ 75 CFM
Tall Bath (9-ft Ceiling)Up to 66 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 25 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.3 kWh/yr (~$0.69/yr)11.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2104.2 kWh/yr (~$16.67/yr)11.9 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta GBR100LED-DECOR?

Compare Delta GBR100LED-DECOR side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter
Utilitech 7115-03 100 / 89.9 CFM 1.5 sones (Same) 7.8 CFM/W 4 in. diameter

Can you size Delta GBR100LED-DECOR for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta GBR100LED-DECOR verified capacity.

Who should not install Delta GBR100LED-DECOR in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta GBR100LED-DECOR for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 75 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.5 sones up to 75 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Delta GBR100LED-DECOR?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta GBR100LED-DECOR.

Does Delta GBR100LED-DECOR satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta GBR100LED-DECOR clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Delta GBR100LED-DECOR undersized or poorly matched for a bath renovation?

Skip Delta GBR100LED-DECOR if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Delta GBR100LED-DECOR CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta GBR100LED-DECOR registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Delta GBR100LED-DECOR sound output compare to noisy contractor-grade fans?

Rated at 1.5 sones, Delta GBR100LED-DECOR produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Delta GBR100LED-DECOR?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Delta GBR100LED-DECOR pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta GBR100LED-DECOR's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta GBR100LED-DECOR?

Delta GBR100LED-DECOR features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta GBR100LED-DECOR's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta GBR100LED-DECOR's safe coverage footprint from 50 sq ft to 44 sq ft.