Skip to main content
Grant Estimator

Greenheck SP-A70 Exhaust Fan Specifications

ENERGY STAR PD #2335043 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

The Greenheck SP-A70 (SP) moves 70 CFM at 0.1 in. w.g. (54 CFM at 0.25 in. w.g.), registers #10 of 607 in quietness (0.1 sones), and delivers 5.1 CFM/W efficacy, sizing bathrooms up to 54 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A70 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 54 CFM
Noise @ 0.1"
0.1 sones (#10/607)
Efficacy Rank
5.1 CFM/W (#507/1,145)
Static Retention
77.1% @ 0.25"
Motor Draw
13.7 W (5.0 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-A70 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 54 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Greenheck maintains 31 active ENERGY STAR blowers; SP-A70 (series: SP) (PD #2335043) gained qualification on 2015-10-15. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.7 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.0 kWh/yr (~$19.20/yr) continuously. Closest competing matches include Cyclone CBP80 (80.0 CFM) and Ortech ODC-8003 (80.0 CFM).

Where does Greenheck SP-A70 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.1 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.1 sone: 0.1 sones (3rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.1 sone: 0.1 sones (P3)

How does duct geometry alter Greenheck SP-A70 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Greenheck SP-A70?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Greenheck SP-A70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-A70 / SP PD ID 2335043 (Qualified 2015-10-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (54 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Greenheck SP-A70 ventilate safely?

Sizing outputs below convert Greenheck SP-A70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A70
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 54 sq ft1 CFM/sq ft @ 54 CFM
Tall Bath (9-ft Ceiling)Up to 48 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.0 kWh/yr (~$0.80/yr)13.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2120.0 kWh/yr (~$19.20/yr)13.7 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Greenheck SP-A70 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Cyclone CBP80 80 / 62.6 CFM 0.2 sones (+0.10) 4.9 CFM/W 4 in. diameter
Ortech ODC-8003 80 / 62.6 CFM 0.2 sones (+0.10) 4.9 CFM/W 4 in. diameter
QuFresh BC80 80 / 62.6 CFM 0.2 sones (+0.10) 4.9 CFM/W 4 in. diameter
Tech Drive TD-BF-06 70 / 60.4 CFM 0.3 sones (+0.20) 4.6 CFM/W 4 in. diameter
Win Air BPT14-13E 70 / 60.4 CFM 0.3 sones (+0.20) 4.6 CFM/W 4 in. diameter

Will Greenheck SP-A70 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Greenheck SP-A70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Greenheck SP-A70 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-A70.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 54 sq ft with 8-ft ceilings (48 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Greenheck SP-A70?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Greenheck SP-A70.

Which bathroom layouts should pick a larger blower than Greenheck SP-A70?

Do not force Greenheck SP-A70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Greenheck SP-A70 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-A70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Greenheck SP-A70 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-A70 at 0.1 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Greenheck SP-A70 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-A70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Greenheck SP-A70 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-A70?

Greenheck SP-A70 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-A70's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A70's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Greenheck SP-A70 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories