The Greenheck SP-A70 (SP) moves 70 CFM at 0.1 in. w.g. (54 CFM at 0.25 in. w.g.), registers #10 of 607 in quietness (0.1 sones), and delivers 5.1 CFM/W efficacy, sizing bathrooms up to 54 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A70 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 54 CFM
- Noise @ 0.1"
- 0.1 sones (#10/607)
- Efficacy Rank
- 5.1 CFM/W (#507/1,145)
- Static Retention
- 77.1% @ 0.25"
- Motor Draw
- 13.7 W (5.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Greenheck SP-A70 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 54 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Greenheck maintains 31 active ENERGY STAR blowers; SP-A70 (series: SP) (PD #2335043) gained qualification on 2015-10-15. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.7 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 120.0 kWh/yr (~$19.20/yr) continuously. Closest competing matches include Cyclone CBP80 (80.0 CFM) and Ortech ODC-8003 (80.0 CFM).
Where does Greenheck SP-A70 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.1 sones against all 1,145 EPA listings.
How does duct geometry alter Greenheck SP-A70 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Greenheck SP-A70?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Greenheck SP-A70 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-A70 / SP | PD ID 2335043 (Qualified 2015-10-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (54 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Greenheck SP-A70 ventilate safely?
Sizing outputs below convert Greenheck SP-A70 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 54 sq ft | 1 CFM/sq ft @ 54 CFM |
| Tall Bath (9-ft Ceiling) | Up to 48 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.0 kWh/yr (~$0.80/yr) | 13.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 120.0 kWh/yr (~$19.20/yr) | 13.7 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Greenheck SP-A70 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Cyclone CBP80 | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| Ortech ODC-8003 | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| QuFresh BC80 | 80 / 62.6 CFM | 0.2 sones (+0.10) | 4.9 CFM/W | 4 in. diameter |
| Tech Drive TD-BF-06 | 70 / 60.4 CFM | 0.3 sones (+0.20) | 4.6 CFM/W | 4 in. diameter |
| Win Air BPT14-13E | 70 / 60.4 CFM | 0.3 sones (+0.20) | 4.6 CFM/W | 4 in. diameter |
Will Greenheck SP-A70 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Greenheck SP-A70 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Greenheck SP-A70 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-A70.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 54 sq ft with 8-ft ceilings (48 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Greenheck SP-A70?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Greenheck SP-A70.
Which bathroom layouts should pick a larger blower than Greenheck SP-A70?
Do not force Greenheck SP-A70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Greenheck SP-A70 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-A70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Greenheck SP-A70 disturb adjacent bedrooms during night use?
Acoustic measurement places Greenheck SP-A70 at 0.1 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Greenheck SP-A70 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-A70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Greenheck SP-A70 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-A70?
Greenheck SP-A70 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-A70's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A70's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Greenheck SP-A70 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)