Skip to main content
Grant Estimator

Ortech ODC-8003 Exhaust Fan Specifications

ENERGY STAR PD #2359270 · Bathroom/Utility Room · Qualified 2020-05-01
Verified Specification Summary

Tested under HVI protocols, the Ortech ODC-8003 exhaust unit achieves 80 CFM at 0.1 in. w.g. (62.6 CFM at 0.25 in. w.g.), registers #18 of 607 in quietness (0.2 sones) and delivers 4.9 CFM/W efficacy, covering standard baths up to 62 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-8003 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62.6 CFM
Noise @ 0.1"
0.2 sones (#18/607)
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
78.2% @ 0.25"
Motor Draw
16.3 W (5.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODC-8003 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.2 sones (#18 of 607 rated models, quietest 3.8% of 607 rated models, quieter than 96.2% of rated models, 0.80 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.6 CFM at 0.25 in. w.g. (78.2% retention, 9.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Ortech maintains 27 active ENERGY STAR blowers; ODC-8003 (series: ODC) (PD #2359270) gained qualification on 2020-05-01. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.3 watts, about 5.9 kWh/yr (~$0.94/yr at $0.16/kWh) for 1 hr/day shower timers or 142.8 kWh/yr (~$22.85/yr) continuously. Closest competing matches include Cyclone CBP80 (80.0 CFM) and QuFresh BC80 (80.0 CFM).

Where do Ortech ODC-8003 sones rank across EPA ENERGY STAR fans?

Comparing Ortech ODC-8003 (0.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.2 sone: 0.2 sones (4th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.2 sone: 0.2 sones (P4)

What attic duct routing preserves Ortech ODC-8003 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Ortech ODC-8003, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Ortech ODC-8003 measure up on airflow and noise ratings?

Each row below breaks down Ortech ODC-8003 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODC-8003 / ODC PD ID 2359270 (Qualified 2020-05-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Ortech ODC-8003 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Ortech ODC-8003
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62.6 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.9 kWh/yr (~$0.94/yr)16.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2142.8 kWh/yr (~$22.85/yr)16.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Ortech ODC-8003?

Compare Ortech ODC-8003 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Cyclone CBP80 80 / 62.6 CFM 0.2 sones (Same) 4.9 CFM/W 4 in. diameter
QuFresh BC80 80 / 62.6 CFM 0.2 sones (Same) 4.9 CFM/W 4 in. diameter
Nektra 33003852 80 / 68.5 CFM 0.3 sones (+0.10) 3.6 CFM/W 4 in. diameter
Wintek BPT15B-80H2 80 / 68.5 CFM 0.3 sones (+0.10) 3.6 CFM/W 4 in. diameter
Greenheck SP-A70 70 / 54 CFM 0.1 sones (-0.10) 5.1 CFM/W 6 in. diameter

Can you size Ortech ODC-8003 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Ortech ODC-8003 verified capacity.

Does Ortech ODC-8003 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech ODC-8003 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 62.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 0.2 sones up to 62 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Ortech ODC-8003?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Ortech ODC-8003.

Who should NOT install Ortech ODC-8003 in a bathroom remodel?

Avoid specifying Ortech ODC-8003 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Ortech ODC-8003 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech ODC-8003 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Ortech ODC-8003 occupy in EPA filings?

With 0.2 sones at 0.1 in. w.g., Ortech ODC-8003 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Ortech ODC-8003 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Ortech ODC-8003 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Ortech ODC-8003 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-8003's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODC-8003?

Ortech ODC-8003 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODC-8003's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-8003's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Ortech ODC-8003 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech ODC-8003 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories