In EPA dataset 8dv7-nngq, Wintek BPT15B-80H2 tests at 80 CFM free discharge (68.5 CFM at 0.25 in. w.g.) and registers #24 of 607 in quietness (0.3 sones) and delivers 3.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 68 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT15B-80H2 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 68.5 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 85.6% @ 0.25"
- Motor Draw
- 22.2 W (8.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Wintek BPT15B-80H2 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.5 CFM out of 80 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Wintek's 9-unit lineup, BPT15B-80H2 (series: BPT15B-80H2) carries PD #3798587 dating to 2024-11-08. Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Nektra 33003852 (80.0 CFM) and Broan RB80 (80.0 CFM).
Does Wintek BPT15B-80H2 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Wintek BPT15B-80H2 at 0.3 sones.
Why avoid unvented attic termination with Wintek BPT15B-80H2?
Under ASHRAE 62.2 best practice, Wintek BPT15B-80H2 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Wintek BPT15B-80H2?
Before cutting ceiling drywall or sizing attic transitions for Wintek BPT15B-80H2, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Wintek (9 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT15B-80H2 / BPT15B-80H2 | PD ID 3798587 (Qualified 2024-11-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (68.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Wintek BPT15B-80H2?
Bathroom ventilation sizing below maps Wintek BPT15B-80H2 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.1 kWh/yr (~$1.30/yr) | 22.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 194.5 kWh/yr (~$31.12/yr) | 22.2 W x 8,760 hrs / 1,000 |
What peer models sit nearest Wintek BPT15B-80H2 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Wintek BPT15B-80H2.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nektra 33003852 | 80 / 68.5 CFM | 0.3 sones (Same) | 3.6 CFM/W | 4 in. diameter |
| Broan RB80 | 80 / 63.1 CFM | 0.3 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| Broan RB80L1 | 80 / 61.2 CFM | 0.3 sones (Same) | 2.9 CFM/W | 4 in. diameter |
| VOTATEC VO-FN4W25-AC-80 | 80 / 66.3 CFM | 0.4 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
| KORA SBF70N | 76.5 / N/A CFM | 0.4 sones (+0.10) | 3.8 CFM/W | 4 in. diameter |
What percentage of room demand does Wintek BPT15B-80H2 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Wintek BPT15B-80H2 tested delivery.
Which bath layouts should avoid specifying Wintek BPT15B-80H2?
Match Wintek BPT15B-80H2 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 68.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.3 sones up to 68 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Wintek BPT15B-80H2?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Wintek BPT15B-80H2.
Where does Wintek BPT15B-80H2 sit on acoustic comfort for senior homeowners?
Measuring 0.3 sones, Wintek BPT15B-80H2 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Wintek BPT15B-80H2 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Wintek BPT15B-80H2 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Wintek BPT15B-80H2 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT15B-80H2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Wintek BPT15B-80H2?
Wintek BPT15B-80H2 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Wintek BPT15B-80H2's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT15B-80H2's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Wintek BPT15B-80H2 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Wintek BPT15B-80H2 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Wintek BPT15B-80H2 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Wintek BPT15B-80H2.
What happens to Wintek BPT15B-80H2 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Wintek BPT15B-80H2 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)