Homeowners specifying VOTATEC VO-FN4W25-AC-80 gain 80 CFM at 0.1 in. w.g. (66.3 CFM at 0.25 in. w.g.) where it registers #50 of 607 in quietness (0.4 sones) and delivers 3.5 CFM/W efficacy, venting bathrooms up to 66 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W25-AC-80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 66.3 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 3.5 CFM/W (#1,038/1,145)
- Static Retention
- 82.9% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VOTATEC VO-FN4W25-AC-80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 66.3 CFM at 0.25 in. w.g. (82.9% retention, 4.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms VOTATEC VO-FN4W25-AC-80 (series: VO-FN4W25-AC-80) under PD #4439171 (4 models registered, 2025-06-06). Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Wintek BPT15B-80H1 (80.0 CFM) and KORA SBF70N (76.5 CFM).
What acoustic percentile does VOTATEC VO-FN4W25-AC-80 occupy among 1,145 bath blowers?
Inspect how VOTATEC VO-FN4W25-AC-80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits VOTATEC VO-FN4W25-AC-80 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around VOTATEC VO-FN4W25-AC-80 housings.
Where do VOTATEC VO-FN4W25-AC-80 acoustic and static metrics stand?
Compare VOTATEC VO-FN4W25-AC-80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VO-FN4W25-AC-80 / VO-FN4W25-AC-80 | PD ID 4439171 (Qualified 2025-06-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (66.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can VOTATEC VO-FN4W25-AC-80 handle taller ceilings or walk-in tub steam?
Evaluate how VOTATEC VO-FN4W25-AC-80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 66 sq ft | 1 CFM/sq ft @ 66.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 58 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near VOTATEC VO-FN4W25-AC-80?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Wintek BPT15B-80H1 | 80 / 66.3 CFM | 0.4 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| KORA SBF70N | 76.5 / N/A CFM | 0.4 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| Nektra 33003852 | 80 / 68.5 CFM | 0.3 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| Wintek BPT15B-80H2 | 80 / 68.5 CFM | 0.3 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
| Broan RB80 | 80 / 63.1 CFM | 0.3 sones (-0.10) | 3.0 CFM/W | 4 in. diameter |
Is VOTATEC VO-FN4W25-AC-80 sized right for your shower or tub room?
Check whether VOTATEC VO-FN4W25-AC-80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Which bath layouts should avoid specifying VOTATEC VO-FN4W25-AC-80?
Match VOTATEC VO-FN4W25-AC-80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 66.3 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for VOTATEC VO-FN4W25-AC-80?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to VOTATEC VO-FN4W25-AC-80.
Where does VOTATEC VO-FN4W25-AC-80 sit on acoustic comfort for senior homeowners?
Measuring 0.4 sones, VOTATEC VO-FN4W25-AC-80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does VOTATEC VO-FN4W25-AC-80 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running VOTATEC VO-FN4W25-AC-80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can VOTATEC VO-FN4W25-AC-80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W25-AC-80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VOTATEC VO-FN4W25-AC-80?
VOTATEC VO-FN4W25-AC-80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VOTATEC VO-FN4W25-AC-80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W25-AC-80's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can VOTATEC VO-FN4W25-AC-80 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W25-AC-80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does VOTATEC VO-FN4W25-AC-80 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with VOTATEC VO-FN4W25-AC-80.
What happens to VOTATEC VO-FN4W25-AC-80 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, VOTATEC VO-FN4W25-AC-80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)