Wintek BPT15B-80H1 Exhaust Fan Specifications

ENERGY STAR PD #3798603 · Bathroom/Utility Room · Qualified 2024-11-08
Verified Specification Summary

In EPA dataset 8dv7-nngq, Wintek BPT15B-80H1 tests at 80 CFM free discharge (66.3 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 3.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 66 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Wintek BPT15B-80H1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 66.3 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
3.5 CFM/W (#1,038/1,145)
Static Retention
82.9% @ 0.25"
Motor Draw
22.9 W (8.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Wintek BPT15B-80H1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 66.3 CFM at 0.25 in. w.g. (82.9% retention, 4.8 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Wintek's 9-unit lineup, BPT15B-80H1 (series: BPT15B-80H1) carries PD #3798603 dating to 2024-11-08. Lighting kit: No. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include VOTATEC VO-FN4W25-AC-80 (80.0 CFM) and KORA SBF70N (76.5 CFM).

Does Wintek BPT15B-80H1 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Wintek BPT15B-80H1 at 0.4 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why avoid unvented attic termination with Wintek BPT15B-80H1?

Under ASHRAE 62.2 best practice, Wintek BPT15B-80H1 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Wintek BPT15B-80H1?

Before cutting ceiling drywall or sizing attic transitions for Wintek BPT15B-80H1, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Wintek (9 models) ENERGY STAR Certified Partner
Model Number & Series BPT15B-80H1 / BPT15B-80H1 PD ID 3798603 (Qualified 2024-11-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (66.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Wintek BPT15B-80H1?

Bathroom ventilation sizing below maps Wintek BPT15B-80H1 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Wintek BPT15B-80H1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 66 sq ft1 CFM/sq ft @ 66.3 CFM
Tall Bath (9-ft Ceiling)Up to 58 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.4 kWh/yr (~$1.34/yr)22.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2200.6 kWh/yr (~$32.10/yr)22.9 W x 8,760 hrs / 1,000

What peer models sit nearest Wintek BPT15B-80H1 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Wintek BPT15B-80H1.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
VOTATEC VO-FN4W25-AC-80 80 / 66.3 CFM 0.4 sones (Same) 3.5 CFM/W 4 in. diameter
KORA SBF70N 76.5 / N/A CFM 0.4 sones (Same) 3.8 CFM/W 4 in. diameter
Nektra 33003852 80 / 68.5 CFM 0.3 sones (-0.10) 3.6 CFM/W 4 in. diameter
Broan RB80 80 / 63.1 CFM 0.3 sones (-0.10) 3.0 CFM/W 4 in. diameter
Broan RB80L1 80 / 61.2 CFM 0.3 sones (-0.10) 2.9 CFM/W 4 in. diameter

What percentage of room demand does Wintek BPT15B-80H1 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Wintek BPT15B-80H1 tested delivery.

Where should contractors skip Wintek BPT15B-80H1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Wintek BPT15B-80H1 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 66.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.4 sones up to 66 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Wintek BPT15B-80H1?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Wintek BPT15B-80H1.

How loud is Wintek BPT15B-80H1 compared with a standard 3.0 sone builder fan?

Tested at 0.4 sones, Wintek BPT15B-80H1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Wintek BPT15B-80H1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Wintek BPT15B-80H1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Wintek BPT15B-80H1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Wintek BPT15B-80H1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Wintek BPT15B-80H1?

Wintek BPT15B-80H1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Wintek BPT15B-80H1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Wintek BPT15B-80H1's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Wintek BPT15B-80H1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Wintek BPT15B-80H1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Wintek BPT15B-80H1?

Rule out Wintek BPT15B-80H1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Wintek BPT15B-80H1 capacity?

Because static drag at 0.25 in. w.g. lowers Wintek BPT15B-80H1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories