Skip to main content
Grant Estimator

KORA SBF70N Exhaust Fan Specifications

ENERGY STAR PD #2399641 · Bathroom/Utility Room · Qualified 2022-07-19
Verified Specification Summary

Homeowners specifying KORA SBF70N gain 76.5 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it registers #50 of 607 in quietness (0.4 sones) and delivers 3.8 CFM/W efficacy, venting bathrooms up to 76 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KORA SBF70N Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
76.5 / N/A CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
0.1" test only
Motor Draw
20.1 W (7.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KORA SBF70N vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 76.5 CFM (#1,007 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

KORA maintains 5 active ENERGY STAR blowers; SBF70N (series: Ceiling Exhaust Fan) (PD #2399641) gained qualification on 2022-07-19. Lighting kit: No. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.1 watts, about 7.3 kWh/yr (~$1.17/yr at $0.16/kWh) for 1 hr/day shower timers or 176.1 kWh/yr (~$28.18/yr) continuously. Closest competing matches include VOTATEC VO-FN4W25-AC-80 (80.0 CFM) and Wintek BPT15B-80H1 (80.0 CFM).

What acoustic percentile does KORA SBF70N occupy among 1,145 bath blowers?

Inspect how KORA SBF70N positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Which exterior damper path suits KORA SBF70N best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around KORA SBF70N housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do KORA SBF70N acoustic and static metrics stand?

Compare KORA SBF70N published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KORA (5 models) ENERGY STAR Certified Partner
Model Number & Series SBF70N / Ceiling Exhaust Fan PD ID 2399641 (Qualified 2022-07-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (76.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can KORA SBF70N handle taller ceilings or walk-in tub steam?

Evaluate how KORA SBF70N scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for KORA SBF70N
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 76 sq ft1 CFM/sq ft @ 76.5 CFM
Tall Bath (9-ft Ceiling)Up to 68 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 26 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.3 kWh/yr (~$1.17/yr)20.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2176.1 kWh/yr (~$28.18/yr)20.1 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near KORA SBF70N?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
VOTATEC VO-FN4W25-AC-80 80 / 66.3 CFM 0.4 sones (Same) 3.5 CFM/W 4 in. diameter
Wintek BPT15B-80H1 80 / 66.3 CFM 0.4 sones (Same) 3.5 CFM/W 4 in. diameter
Nektra 33003852 80 / 68.5 CFM 0.3 sones (-0.10) 3.6 CFM/W 4 in. diameter
Wintek BPT15B-80H2 80 / 68.5 CFM 0.3 sones (-0.10) 3.6 CFM/W 4 in. diameter
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter

Is KORA SBF70N sized right for your shower or tub room?

Check whether KORA SBF70N clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out KORA SBF70N?

Compare where KORA SBF70N excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 26 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 76.5 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for KORA SBF70N?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KORA SBF70N.

Is KORA SBF70N quiet enough for a primary bedroom bathroom?

At 0.4 sones, KORA SBF70N operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is KORA SBF70N energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can KORA SBF70N pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KORA SBF70N's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KORA SBF70N?

KORA SBF70N features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KORA SBF70N's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KORA SBF70N's safe coverage footprint from 50 sq ft to 44 sq ft.

Can KORA SBF70N serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: KORA SBF70N supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap KORA SBF70N for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, KORA SBF70N lacks adequate reserve.

How does KORA SBF70N handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., KORA SBF70N yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories