Skip to main content
Grant Estimator

AERO PURE ABF80G15W Exhaust Fan Specifications

ENERGY STAR PD #4587269 · Bathroom/Utility Room · Qualified 2026-04-08
Verified Specification Summary

Certified by EPA ENERGY STAR, AERO PURE ABF80G15W delivers 80 CFM free-air (62.9 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 62 sq ft (8-ft height) or 55 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF80G15W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62.9 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
78.6% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AERO PURE ABF80G15W vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4587269 verifies ABF80G15W (series: ABF80G) under AERO PURE (14 listed models, qualified 2026-04-08). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AUPU AV08A1 (80.0 CFM) and Broan QTXEG080 (80.0 CFM).

How noisy is AERO PURE ABF80G15W compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AERO PURE ABF80G15W measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 4 in. diameter ducting protect AERO PURE ABF80G15W airflow?

Connecting AERO PURE ABF80G15W through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify AERO PURE ABF80G15W performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AERO PURE ABF80G15W lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AERO PURE (14 models) ENERGY STAR Certified Partner
Model Number & Series ABF80G15W / ABF80G PD ID 4587269 (Qualified 2026-04-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit AERO PURE ABF80G15W?

Calculated coverage metrics translate AERO PURE ABF80G15W airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF80G15W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62.9 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to AERO PURE ABF80G15W?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AUPU AV08A1 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
Broan QTXEG080 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter
Broan QTXEG080 = QTXEGH with QTXEG080F 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter
Broan QTXEG080X 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter
Broan QTXEG080X = QTXEGH with QTXEG080FX 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter

Does AERO PURE ABF80G15W match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AERO PURE ABF80G15W percentage capacity without sending data.

What plumbing or duct constraints rule out AERO PURE ABF80G15W?

Compare where AERO PURE ABF80G15W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 62.9 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for AERO PURE ABF80G15W?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AERO PURE ABF80G15W.

Why might a contractor swap AERO PURE ABF80G15W for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AERO PURE ABF80G15W lacks adequate reserve.

How does AERO PURE ABF80G15W handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AERO PURE ABF80G15W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is AERO PURE ABF80G15W quiet enough for a primary bedroom bathroom?

At 0.4 sones, AERO PURE ABF80G15W operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is AERO PURE ABF80G15W energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can AERO PURE ABF80G15W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF80G15W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AERO PURE ABF80G15W?

AERO PURE ABF80G15W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AERO PURE ABF80G15W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF80G15W's safe coverage footprint from 50 sq ft to 44 sq ft.

Can AERO PURE ABF80G15W serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AERO PURE ABF80G15W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories