Broan QTXEG080 = QTXEGH with QTXEG080F Exhaust Fan Specifications

ENERGY STAR PD #4697974 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Tested under HVI protocols, the Broan QTXEG080 = QTXEGH with QTXEG080F exhaust unit achieves 80 CFM at 0.1 in. w.g. (85.6 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 85 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG080 = QTXEGH with QTXEG080F Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 85.6 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
107.0% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QTXEG080 = QTXEGH with QTXEG080F vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85.6 CFM out of 80 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Broan maintains 207 active ENERGY STAR blowers; QTXEG080 = QTXEGH with QTXEG080F (series: QT SERIES) (PD #4697974) gained qualification on 2026-09-02. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).

Where do Broan QTXEG080 = QTXEGH with QTXEG080F sones rank across EPA ENERGY STAR fans?

Comparing Broan QTXEG080 = QTXEGH with QTXEG080F (0.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

What attic duct routing preserves Broan QTXEG080 = QTXEGH with QTXEG080F CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QTXEG080 = QTXEGH with QTXEG080F, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan QTXEG080 = QTXEGH with QTXEG080F measure up on airflow and noise ratings?

Each row below breaks down Broan QTXEG080 = QTXEGH with QTXEG080F certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QTXEG080 = QTXEGH with QTXEG080F / QT SERIES PD ID 4697974 (Qualified 2026-09-02)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan QTXEG080 = QTXEGH with QTXEG080F CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan QTXEG080 = QTXEGH with QTXEG080F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85.6 CFM
Tall Bath (9-ft Ceiling)Up to 76 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan QTXEG080 = QTXEGH with QTXEG080F?

Compare Broan QTXEG080 = QTXEGH with QTXEG080F side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AUPU AV08A1 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
Air King AK80LS6 80 / 59.6 CFM 0.5 sones (+0.10) 4.7 CFM/W 6 in. diameter
Air King AK80LS6H 80 / 59.6 CFM 0.5 sones (+0.10) 4.7 CFM/W 6 in. diameter

Can you size Broan QTXEG080 = QTXEGH with QTXEG080F for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QTXEG080 = QTXEGH with QTXEG080F verified capacity.

Does Broan QTXEG080 = QTXEGH with QTXEG080F suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXEG080 = QTXEGH with QTXEG080F for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 85.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 0.4 sones up to 85 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Broan QTXEG080 = QTXEGH with QTXEG080F?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QTXEG080 = QTXEGH with QTXEG080F.

What acoustic sone tier does Broan QTXEG080 = QTXEGH with QTXEG080F occupy in EPA filings?

With 0.4 sones at 0.1 in. w.g., Broan QTXEG080 = QTXEGH with QTXEG080F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Broan QTXEG080 = QTXEGH with QTXEG080F add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan QTXEG080 = QTXEGH with QTXEG080F averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan QTXEG080 = QTXEGH with QTXEG080F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG080 = QTXEGH with QTXEG080F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QTXEG080 = QTXEGH with QTXEG080F?

Broan QTXEG080 = QTXEGH with QTXEG080F features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QTXEG080 = QTXEGH with QTXEG080F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG080 = QTXEGH with QTXEG080F's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan QTXEG080 = QTXEGH with QTXEG080F pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG080 = QTXEGH with QTXEG080F easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan QTXEG080 = QTXEGH with QTXEG080F in a bathroom remodel?

Avoid specifying Broan QTXEG080 = QTXEGH with QTXEG080F in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan QTXEG080 = QTXEGH with QTXEG080F airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXEG080 = QTXEGH with QTXEG080F achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories