Tested under HVI protocols, the Broan QTXEG080 = QTXEGH with QTXEG080F exhaust unit achieves 80 CFM at 0.1 in. w.g. (85.6 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 85 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG080 = QTXEGH with QTXEG080F Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 85.6 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 107.0% @ 0.25"
- Motor Draw
- 17.0 W (6.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QTXEG080 = QTXEGH with QTXEG080F vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85.6 CFM out of 80 CFM (107.0% retention, 19.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Broan maintains 207 active ENERGY STAR blowers; QTXEG080 = QTXEGH with QTXEG080F (series: QT SERIES) (PD #4697974) gained qualification on 2026-09-02. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).
Where do Broan QTXEG080 = QTXEGH with QTXEG080F sones rank across EPA ENERGY STAR fans?
Comparing Broan QTXEG080 = QTXEGH with QTXEG080F (0.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan QTXEG080 = QTXEGH with QTXEG080F CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QTXEG080 = QTXEGH with QTXEG080F, preventing premature peeling paint and mold growth.
How does Broan QTXEG080 = QTXEGH with QTXEG080F measure up on airflow and noise ratings?
Each row below breaks down Broan QTXEG080 = QTXEGH with QTXEG080F certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QTXEG080 = QTXEGH with QTXEG080F / QT SERIES | PD ID 4697974 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (85.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan QTXEG080 = QTXEGH with QTXEG080F CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 76 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.9 kWh/yr (~$23.82/yr) | 17.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan QTXEG080 = QTXEGH with QTXEG080F?
Compare Broan QTXEG080 = QTXEGH with QTXEG080F side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AERO PURE ABF80G15W | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| AERO PURE ABF80G16W | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| AUPU AV08A1 | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Air King AK80LS6 | 80 / 59.6 CFM | 0.5 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| Air King AK80LS6H | 80 / 59.6 CFM | 0.5 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
Can you size Broan QTXEG080 = QTXEGH with QTXEG080F for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QTXEG080 = QTXEGH with QTXEG080F verified capacity.
Does Broan QTXEG080 = QTXEGH with QTXEG080F suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXEG080 = QTXEGH with QTXEG080F for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 85.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 0.4 sones up to 85 sq ft
- Best application: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan QTXEG080 = QTXEGH with QTXEG080F?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QTXEG080 = QTXEGH with QTXEG080F.
What acoustic sone tier does Broan QTXEG080 = QTXEGH with QTXEG080F occupy in EPA filings?
With 0.4 sones at 0.1 in. w.g., Broan QTXEG080 = QTXEGH with QTXEG080F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Broan QTXEG080 = QTXEGH with QTXEG080F add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan QTXEG080 = QTXEGH with QTXEG080F averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan QTXEG080 = QTXEGH with QTXEG080F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG080 = QTXEGH with QTXEG080F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QTXEG080 = QTXEGH with QTXEG080F?
Broan QTXEG080 = QTXEGH with QTXEG080F features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QTXEG080 = QTXEGH with QTXEG080F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG080 = QTXEGH with QTXEG080F's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan QTXEG080 = QTXEGH with QTXEG080F pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG080 = QTXEGH with QTXEG080F easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan QTXEG080 = QTXEGH with QTXEG080F in a bathroom remodel?
Avoid specifying Broan QTXEG080 = QTXEGH with QTXEG080F in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan QTXEG080 = QTXEGH with QTXEG080F airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXEG080 = QTXEGH with QTXEG080F achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)