Homeowners specifying Air King AK80LS6H gain 80 CFM at 0.1 in. w.g. (59.6 CFM at 0.25 in. w.g.) where it registers #83 of 607 in quietness (0.5 sones) and delivers 4.7 CFM/W efficacy, venting bathrooms up to 59 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK80LS6H Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 59.6 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 74.5% @ 0.25"
- Motor Draw
- 17.0 W (6.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King AK80LS6H vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.6 CFM at 0.25 in. w.g. (74.5% retention, 13.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Air King's 62-unit lineup, AK80LS6H (series: Air King) carries PD #2382124 dating to 2021-06-04. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).
What acoustic percentile does Air King AK80LS6H occupy among 1,145 bath blowers?
Inspect how Air King AK80LS6H positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Air King AK80LS6H best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Air King AK80LS6H housings.
Where do Air King AK80LS6H acoustic and static metrics stand?
Compare Air King AK80LS6H published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK80LS6H / Air King | PD ID 2382124 (Qualified 2021-06-04) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (59.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Air King AK80LS6H handle taller ceilings or walk-in tub steam?
Evaluate how Air King AK80LS6H scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.9 kWh/yr (~$23.82/yr) | 17.0 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Air King AK80LS6H?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AERO PURE ABF80G15W | 80 / 62.9 CFM | 0.4 sones (-0.10) | 4.7 CFM/W | 4 in. diameter |
| AERO PURE ABF80G16W | 80 / 62.9 CFM | 0.4 sones (-0.10) | 4.7 CFM/W | 4 in. diameter |
| AUPU AV08A1 | 80 / 62.9 CFM | 0.4 sones (-0.10) | 4.7 CFM/W | 4 in. diameter |
| Broan QTXEG080 | 80 / 85.6 CFM | 0.4 sones (-0.10) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG080 = QTXEGH with QTXEG080F | 80 / 85.6 CFM | 0.4 sones (-0.10) | 4.7 CFM/W | 6 in. diameter |
Is Air King AK80LS6H sized right for your shower or tub room?
Check whether Air King AK80LS6H clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does Air King AK80LS6H suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King AK80LS6H for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 59.6 CFM net static output
- Best application: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Air King AK80LS6H?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Air King AK80LS6H.
Does duct resistance cut Air King AK80LS6H airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King AK80LS6H achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Air King AK80LS6H occupy in EPA filings?
With 0.5 sones at 0.1 in. w.g., Air King AK80LS6H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Air King AK80LS6H add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Air King AK80LS6H averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Air King AK80LS6H pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK80LS6H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK80LS6H?
Air King AK80LS6H features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK80LS6H's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK80LS6H's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King AK80LS6H pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King AK80LS6H easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Air King AK80LS6H in a bathroom remodel?
Avoid specifying Air King AK80LS6H in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)