In EPA dataset 8dv7-nngq, Dayton 1UBH6B tests at 70 CFM free discharge (unpublished 0.25 in. w.g. output) and registers #83 of 607 in quietness (0.5 sones) and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 70 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 1UBH6B Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / N/A CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 15.9 W (5.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Dayton 1UBH6B vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Free-discharge delivery reaches 70 CFM (#1,009 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Dayton's 12-unit lineup, 1UBH6B (series: 1UBH6B) carries PD #2335077 dating to 2015-10-15. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.9 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 139.3 kWh/yr (~$22.29/yr) continuously. Closest competing matches include Greenheck SP-B70 (70.0 CFM) and Greenheck SP-B50 (63.0 CFM).
Does Dayton 1UBH6B fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Dayton 1UBH6B at 0.5 sones.
Why avoid unvented attic termination with Dayton 1UBH6B?
Under ASHRAE 62.2 best practice, Dayton 1UBH6B needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Dayton 1UBH6B?
Before cutting ceiling drywall or sizing attic transitions for Dayton 1UBH6B, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Dayton (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 1UBH6B / 1UBH6B | PD ID 2335077 (Qualified 2015-10-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Dayton 1UBH6B?
Bathroom ventilation sizing below maps Dayton 1UBH6B motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.8 kWh/yr (~$0.93/yr) | 15.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 139.3 kWh/yr (~$22.29/yr) | 15.9 W x 8,760 hrs / 1,000 |
What peer models sit nearest Dayton 1UBH6B in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Dayton 1UBH6B.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Greenheck SP-B70 | 70 / 54 CFM | 0.5 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| Greenheck SP-B50 | 63 / N/A CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 6 in. diameter |
| KORA SBF70N | 76.5 / N/A CFM | 0.4 sones (-0.10) | 3.8 CFM/W | 4 in. diameter |
| Air King AK80LS6 | 80 / 59.6 CFM | 0.5 sones (Same) | 4.7 CFM/W | 6 in. diameter |
| Air King AK80LS6H | 80 / 59.6 CFM | 0.5 sones (Same) | 4.7 CFM/W | 6 in. diameter |
What percentage of room demand does Dayton 1UBH6B cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Dayton 1UBH6B tested delivery.
Which bath layouts should avoid specifying Dayton 1UBH6B?
Match Dayton 1UBH6B directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 70 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.5 sones up to 70 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Dayton 1UBH6B?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Dayton 1UBH6B.
What happens to Dayton 1UBH6B CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Dayton 1UBH6B moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Dayton 1UBH6B sit on acoustic comfort for senior homeowners?
Measuring 0.5 sones, Dayton 1UBH6B operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Dayton 1UBH6B cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Dayton 1UBH6B 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Dayton 1UBH6B pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 1UBH6B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Dayton 1UBH6B?
Dayton 1UBH6B features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Dayton 1UBH6B's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 1UBH6B's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Dayton 1UBH6B ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Dayton 1UBH6B covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Dayton 1UBH6B run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Dayton 1UBH6B.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)