Homeowners specifying Greenheck SP-B70 gain 70 CFM at 0.1 in. w.g. (54 CFM at 0.25 in. w.g.) where it registers #83 of 607 in quietness (0.5 sones) and delivers 4.4 CFM/W efficacy, venting bathrooms up to 54 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-B70 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 54 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 77.1% @ 0.25"
- Motor Draw
- 15.9 W (5.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Greenheck SP-B70 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 70 CFM open-air to 54 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Greenheck SP-B70 (series: SP) under PD #2335039 (31 models registered, 2015-10-15). Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.9 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 139.3 kWh/yr (~$22.29/yr) continuously. Closest competing matches include Dayton 1UBH6B (70.0 CFM) and Dayton 3DPE2 (63.0 CFM).
What acoustic percentile does Greenheck SP-B70 occupy among 1,145 bath blowers?
Inspect how Greenheck SP-B70 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Greenheck SP-B70 best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Greenheck SP-B70 housings.
Where do Greenheck SP-B70 acoustic and static metrics stand?
Compare Greenheck SP-B70 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-B70 / SP | PD ID 2335039 (Qualified 2015-10-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (54 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Greenheck SP-B70 handle taller ceilings or walk-in tub steam?
Evaluate how Greenheck SP-B70 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 54 sq ft | 1 CFM/sq ft @ 54 CFM |
| Tall Bath (9-ft Ceiling) | Up to 48 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.8 kWh/yr (~$0.93/yr) | 15.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 139.3 kWh/yr (~$22.29/yr) | 15.9 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Greenheck SP-B70?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 1UBH6B | 70 / N/A CFM | 0.5 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| Dayton 3DPE2 | 63 / N/A CFM | 0.4 sones (-0.10) | 4.0 CFM/W | 6 in. diameter |
| KORA SBF70N | 76.5 / N/A CFM | 0.4 sones (-0.10) | 3.8 CFM/W | 4 in. diameter |
| Air King AK80LS6 | 80 / 59.6 CFM | 0.5 sones (Same) | 4.7 CFM/W | 6 in. diameter |
| Air King AK80LS6H | 80 / 59.6 CFM | 0.5 sones (Same) | 4.7 CFM/W | 6 in. diameter |
Is Greenheck SP-B70 sized right for your shower or tub room?
Check whether Greenheck SP-B70 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Greenheck SP-B70 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-B70.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 54 CFM net static output
- Target scenario: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Greenheck SP-B70?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-B70.
Will Greenheck SP-B70 disturb adjacent bedrooms during night use?
Acoustic measurement places Greenheck SP-B70 at 0.5 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Greenheck SP-B70 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-B70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Greenheck SP-B70 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-B70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-B70?
Greenheck SP-B70 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-B70's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-B70's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Greenheck SP-B70 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-B70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Greenheck SP-B70?
Do not force Greenheck SP-B70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Greenheck SP-B70 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-B70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)