Skip to main content
Grant Estimator

Greenheck SP-B70 Exhaust Fan Specifications

ENERGY STAR PD #2335039 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Homeowners specifying Greenheck SP-B70 gain 70 CFM at 0.1 in. w.g. (54 CFM at 0.25 in. w.g.) where it registers #83 of 607 in quietness (0.5 sones) and delivers 4.4 CFM/W efficacy, venting bathrooms up to 54 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-B70 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 54 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
77.1% @ 0.25"
Motor Draw
15.9 W (5.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-B70 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 54 CFM at 0.25 in. w.g. (77.1% retention, 10.6 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Greenheck SP-B70 (series: SP) under PD #2335039 (31 models registered, 2015-10-15). Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 15.9 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 139.3 kWh/yr (~$22.29/yr) continuously. Closest competing matches include Dayton 1UBH6B (70.0 CFM) and Dayton 3DPE2 (63.0 CFM).

What acoustic percentile does Greenheck SP-B70 occupy among 1,145 bath blowers?

Inspect how Greenheck SP-B70 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

Which exterior damper path suits Greenheck SP-B70 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Greenheck SP-B70 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Greenheck SP-B70 acoustic and static metrics stand?

Compare Greenheck SP-B70 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-B70 / SP PD ID 2335039 (Qualified 2015-10-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (54 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Greenheck SP-B70 handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck SP-B70 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck SP-B70
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 54 sq ft1 CFM/sq ft @ 54 CFM
Tall Bath (9-ft Ceiling)Up to 48 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.8 kWh/yr (~$0.93/yr)15.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2139.3 kWh/yr (~$22.29/yr)15.9 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Greenheck SP-B70?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 1UBH6B 70 / N/A CFM 0.5 sones (Same) 4.4 CFM/W 6 in. diameter
Dayton 3DPE2 63 / N/A CFM 0.4 sones (-0.10) 4.0 CFM/W 6 in. diameter
KORA SBF70N 76.5 / N/A CFM 0.4 sones (-0.10) 3.8 CFM/W 4 in. diameter
Air King AK80LS6 80 / 59.6 CFM 0.5 sones (Same) 4.7 CFM/W 6 in. diameter
Air King AK80LS6H 80 / 59.6 CFM 0.5 sones (Same) 4.7 CFM/W 6 in. diameter

Is Greenheck SP-B70 sized right for your shower or tub room?

Check whether Greenheck SP-B70 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

When does Greenheck SP-B70 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck SP-B70.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 54 CFM net static output
  • Target scenario: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Greenheck SP-B70?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-B70.

Will Greenheck SP-B70 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck SP-B70 at 0.5 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Greenheck SP-B70 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck SP-B70 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Greenheck SP-B70 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-B70's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-B70?

Greenheck SP-B70 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-B70's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-B70's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Greenheck SP-B70 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-B70 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Greenheck SP-B70?

Do not force Greenheck SP-B70 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Greenheck SP-B70 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck SP-B70 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories