Air King AK80LS6 Exhaust Fan Specifications

ENERGY STAR PD #2382123 · Bathroom/Utility Room · Qualified 2021-06-04
Verified Specification Summary

The Air King AK80LS6 (Air King) moves 80 CFM at 0.1 in. w.g. (59.6 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones), and delivers 4.7 CFM/W efficacy, sizing bathrooms up to 59 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK80LS6 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 59.6 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
74.5% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King AK80LS6 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.6 CFM at 0.25 in. w.g. (74.5% retention, 13.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #2382123 verifies AK80LS6 (series: Air King) under Air King (62 listed models, qualified 2021-06-04). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).

Where does Air King AK80LS6 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

How does duct geometry alter Air King AK80LS6 static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Air King AK80LS6?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King AK80LS6 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series AK80LS6 / Air King PD ID 2382123 (Qualified 2021-06-04)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (59.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Air King AK80LS6 ventilate safely?

Sizing outputs below convert Air King AK80LS6 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Air King AK80LS6
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 59 sq ft1 CFM/sq ft @ 59.6 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Air King AK80LS6 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (-0.10) 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80 / 62.9 CFM 0.4 sones (-0.10) 4.7 CFM/W 4 in. diameter
AUPU AV08A1 80 / 62.9 CFM 0.4 sones (-0.10) 4.7 CFM/W 4 in. diameter
Broan QTXEG080 80 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG080 = QTXEGH with QTXEG080F 80 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter

Will Air King AK80LS6 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Air King AK80LS6 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Air King AK80LS6 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King AK80LS6.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 59 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Air King AK80LS6?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King AK80LS6.

How much airflow does Air King AK80LS6 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Air King AK80LS6 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.

Will Air King AK80LS6 disturb adjacent bedrooms during night use?

Acoustic measurement places Air King AK80LS6 at 0.5 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Air King AK80LS6 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Air King AK80LS6 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Air King AK80LS6 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK80LS6's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King AK80LS6?

Air King AK80LS6 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King AK80LS6's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK80LS6's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Air King AK80LS6 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King AK80LS6 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Air King AK80LS6?

Do not force Air King AK80LS6 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.