Skip to main content
Grant Estimator

Kaze Appliance SEP120 Exhaust Fan Specifications

ENERGY STAR PD #2524270 · Bathroom/Utility Room · Qualified 2023-06-23
Verified Specification Summary

The Kaze Appliance SEP120 (SEP) moves 100 CFM at 0.1 in. w.g. (83.8 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones), and delivers 3.6 CFM/W efficacy, sizing bathrooms up to 83 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Kaze Appliance SEP120 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 83.8 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
83.8% @ 0.25"
Motor Draw
27.8 W (10.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Kaze Appliance SEP120 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.8 CFM at 0.25 in. w.g. (83.8% retention, 3.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Kaze Appliance SEP120 (series: SEP) under PD #2524270 (4 models registered, 2023-06-23). Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.8 watts, about 10.1 kWh/yr (~$1.62/yr at $0.16/kWh) for 1 hr/day shower timers or 243.5 kWh/yr (~$38.96/yr) continuously. Closest competing matches include Broan RB110 (110.0 CFM) and Nutone RN110 (110.0 CFM).

Where does Kaze Appliance SEP120 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.5 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

How does duct geometry alter Kaze Appliance SEP120 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Kaze Appliance SEP120?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Kaze Appliance SEP120 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Kaze Appliance (4 models) ENERGY STAR Certified Partner
Model Number & Series SEP120 / SEP PD ID 2524270 (Qualified 2023-06-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (83.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Kaze Appliance SEP120 ventilate safely?

Sizing outputs below convert Kaze Appliance SEP120 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Kaze Appliance SEP120
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 83 sq ft1 CFM/sq ft @ 83.8 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 33 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.1 kWh/yr (~$1.62/yr)27.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2243.5 kWh/yr (~$38.96/yr)27.8 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Kaze Appliance SEP120 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan RB110 110 / 91 CFM 0.4 sones (-0.10) 3.7 CFM/W 4 in. diameter
Nutone RN110 110 / 91 CFM 0.4 sones (-0.10) 3.7 CFM/W 4 in. diameter
Broan QTXEG110 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110 = QTXEGH with QTXEG110F 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110S 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter

Will Kaze Appliance SEP120 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Kaze Appliance SEP120 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Kaze Appliance SEP120?

Match Kaze Appliance SEP120 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 33 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 83 sq ft with 8-ft ceilings (74 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Kaze Appliance SEP120?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Kaze Appliance SEP120.

What does Kaze Appliance SEP120 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Kaze Appliance SEP120 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Kaze Appliance SEP120 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Kaze Appliance SEP120's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Kaze Appliance SEP120?

Kaze Appliance SEP120 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Kaze Appliance SEP120's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Kaze Appliance SEP120's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Kaze Appliance SEP120 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Kaze Appliance SEP120 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Kaze Appliance SEP120 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Kaze Appliance SEP120.

What happens to Kaze Appliance SEP120 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Kaze Appliance SEP120 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Kaze Appliance SEP120 sit on acoustic comfort for senior homeowners?

Measuring 0.5 sones, Kaze Appliance SEP120 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories