Skip to main content
Grant Estimator

Panasonic Eco Solutions RG-E110THA Exhaust Fan Specifications

ENERGY STAR PD #2669650 · Bathroom/Utility Room · Qualified 2023-07-21
Verified Specification Summary

Rated for 110 CFM open-air (110.3 CFM at 0.25 in. w.g.), Panasonic Eco Solutions RG-E110THA registers #83 of 607 in quietness (0.5 sones) and delivers 9.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 110 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic Eco Solutions RG-E110THA Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 110.3 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
9.9 CFM/W (#189/1,145)
Static Retention
100.3% @ 0.25"
Motor Draw
11.1 W (4.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic Eco Solutions RG-E110THA vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.3 CFM out of 110 CFM (100.3% retention, 12.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2669650 verifies RG-E110THA (series: Whisper Suite) under Panasonic Eco Solutions (9 listed models, qualified 2023-07-21). Lighting kit: No. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.1 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 97.2 kWh/yr (~$15.55/yr) continuously. Closest competing matches include Delta 110LED-ADJ (110.0 CFM) and Delta SIG110 (110.0 CFM).

How does Panasonic Eco Solutions RG-E110THA acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Panasonic Eco Solutions RG-E110THA (0.5 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

How do flex elbows choke Panasonic Eco Solutions RG-E110THA at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic Eco Solutions RG-E110THA moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Panasonic Eco Solutions RG-E110THA meet residential exhaust fan code specs?

Inspect Panasonic Eco Solutions RG-E110THA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic Eco Solutions (9 models) ENERGY STAR Certified Partner
Model Number & Series RG-E110THA / Whisper Suite PD ID 2669650 (Qualified 2023-07-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Panasonic Eco Solutions RG-E110THA airflow output?

Annual electricity figures and room square-footage ceilings below reflect Panasonic Eco Solutions RG-E110THA tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Panasonic Eco Solutions RG-E110THA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.3 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.1 kWh/yr (~$0.66/yr)11.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.297.2 kWh/yr (~$15.55/yr)11.1 W x 8,760 hrs / 1,000

Which competing models share Panasonic Eco Solutions RG-E110THA airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta 110LED-ADJ 110 / 98.1 CFM 0.4 sones (-0.10) 8.3 CFM/W 4 in. diameter
Delta SIG110 110 / 96.5 CFM 0.3 sones (-0.20) 9.0 CFM/W 4 in. diameter
KORA SBF90DC-MS 98.1 / N/A CFM 0.7 sones (+0.20) 10.7 CFM/W 4 in. diameter
Broan (Canada) XB110L1 110 / 110.3 CFM 0.3 sones (-0.20) 12.6 CFM/W 6 in. diameter
Broan XB110HL1 110 / 110.3 CFM 0.3 sones (-0.20) 12.6 CFM/W 6 in. diameter

How much airflow margin does Panasonic Eco Solutions RG-E110THA give your bath?

Run a quick local room-volume check for Panasonic Eco Solutions RG-E110THA by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Panasonic Eco Solutions RG-E110THA?

Match Panasonic Eco Solutions RG-E110THA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 110 sq ft with 8-ft ceilings (98 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Panasonic Eco Solutions RG-E110THA?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic Eco Solutions RG-E110THA.

What happens to Panasonic Eco Solutions RG-E110THA CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic Eco Solutions RG-E110THA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Panasonic Eco Solutions RG-E110THA sit on acoustic comfort for senior homeowners?

Measuring 0.5 sones, Panasonic Eco Solutions RG-E110THA operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic Eco Solutions RG-E110THA cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic Eco Solutions RG-E110THA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic Eco Solutions RG-E110THA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic Eco Solutions RG-E110THA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic Eco Solutions RG-E110THA?

Panasonic Eco Solutions RG-E110THA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic Eco Solutions RG-E110THA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic Eco Solutions RG-E110THA's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic Eco Solutions RG-E110THA ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic Eco Solutions RG-E110THA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Panasonic Eco Solutions RG-E110THA run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic Eco Solutions RG-E110THA.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories