Dayton 5AE70B Exhaust Fan Specifications

ENERGY STAR PD #2335083 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Tested under HVI protocols, the Dayton 5AE70B exhaust unit achieves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), registers #83 of 607 in quietness (0.5 sones) and delivers 6.2 CFM/W efficacy, covering standard baths up to 120 sq ft on a 6 x 8 in. rectangular collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 5AE70B Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
6.2 CFM/W (#446/1,145)
Static Retention
0.1" test only
Motor Draw
19.4 W (7.1 kWh/yr)
Duct & Tier
6 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 5AE70B vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 6 x 8 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Certification audit confirms Dayton 5AE70B (series: 5AE70B) under PD #2335083 (12 models registered, 2015-10-15). Lighting kit: No. At 6.2 CFM/W (#446 of 1,145, top 39.0% of 1,145 rated models, more efficient than 61.0% of rated models, 1.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 19.4 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 169.9 kWh/yr (~$27.18/yr) continuously. Closest competing matches include Broan QTXEG110 (110.0 CFM) and Broan QTXEG110 = QTXEGH with QTXEG110F (110.0 CFM).

Where do Dayton 5AE70B sones rank across EPA ENERGY STAR fans?

Comparing Dayton 5AE70B (0.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

What attic duct routing preserves Dayton 5AE70B CFM output?

Short straight 6 x 8 in. rectangular duct paths retain up to ~82% of open-air capacity on Dayton 5AE70B, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Dayton 5AE70B measure up on airflow and noise ratings?

Each row below breaks down Dayton 5AE70B certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 5AE70B / 5AE70B PD ID 2335083 (Qualified 2015-10-15)
Duct Connection 6 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Dayton 5AE70B CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Dayton 5AE70B
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.1 kWh/yr (~$1.14/yr)19.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2169.9 kWh/yr (~$27.18/yr)19.4 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Dayton 5AE70B?

Compare Dayton 5AE70B side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QTXEG110 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110 = QTXEGH with QTXEG110F 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110S 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110S = QTXEGSH with QTXEG110SF 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110SX 110 / 85.6 CFM 0.4 sones (-0.10) 4.7 CFM/W 6 in. diameter

Can you size Dayton 5AE70B for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Dayton 5AE70B verified capacity.

Where should contractors skip Dayton 5AE70B on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Dayton 5AE70B carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 120 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.5 sones up to 120 sq ft
  • Works well for: Paired with rigid galvanized 6 x 8 in. rectangular transition

How do federal and code standards apply to Dayton 5AE70B?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Dayton 5AE70B.

Will long attic ducting choke Dayton 5AE70B capacity?

Because static drag at 0.25 in. w.g. lowers Dayton 5AE70B from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 x 8 in. rectangular rigid ducting straight to a dedicated exterior damper.

How loud is Dayton 5AE70B compared with a standard 3.0 sone builder fan?

Tested at 0.5 sones, Dayton 5AE70B operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Dayton 5AE70B consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Dayton 5AE70B draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Dayton 5AE70B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 5AE70B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 5AE70B?

Dayton 5AE70B features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 5AE70B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 5AE70B's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Dayton 5AE70B score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Dayton 5AE70B delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Dayton 5AE70B?

Rule out Dayton 5AE70B when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.