The Broan QTXEG110S = QTXEGSH with QTXEG110SF (QT SERIES) moves 110 CFM at 0.1 in. w.g. (85.6 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones), and delivers 4.7 CFM/W efficacy, sizing bathrooms up to 85 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG110S = QTXEGSH with QTXEG110SF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 85.6 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 77.8% @ 0.25"
- Motor Draw
- 23.4 W (8.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QTXEG110S = QTXEGSH with QTXEG110SF vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 85.6 CFM at 0.25 in. w.g. (77.8% retention, 9.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Broan maintains 207 active ENERGY STAR blowers; QTXEG110S = QTXEGSH with QTXEG110SF (series: QT SERIES) (PD #3629729) gained qualification on 2024-09-27. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 23.4 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 205.0 kWh/yr (~$32.80/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (120.0 CFM).
Where does Broan QTXEG110S = QTXEGSH with QTXEG110SF sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.4 sones against all 1,145 EPA listings.
How does duct geometry alter Broan QTXEG110S = QTXEGSH with QTXEG110SF static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan QTXEG110S = QTXEGSH with QTXEG110SF?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan QTXEG110S = QTXEGSH with QTXEG110SF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QTXEG110S = QTXEGSH with QTXEG110SF / QT SERIES | PD ID 3629729 (Qualified 2024-09-27) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (85.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan QTXEG110S = QTXEGSH with QTXEG110SF ventilate safely?
Sizing outputs below convert Broan QTXEG110S = QTXEGSH with QTXEG110SF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 76 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.5 kWh/yr (~$1.36/yr) | 23.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 205.0 kWh/yr (~$32.80/yr) | 23.4 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan QTXEG110S = QTXEGSH with QTXEG110SF closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone RN110 | 110 / 91 CFM | 0.4 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Kaze Appliance SEP120 | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| S&P PC110XP | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| Kaze Appliance SEP120 | 100 / 83.8 CFM | 0.5 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| Dayton 5AE70B | 120 / N/A CFM | 0.5 sones (+0.10) | 6.2 CFM/W | 6 x 8 in. rectangular |
Will Broan QTXEG110S = QTXEGSH with QTXEG110SF clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan QTXEG110S = QTXEGSH with QTXEG110SF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does Broan QTXEG110S = QTXEGSH with QTXEG110SF suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan QTXEG110S = QTXEGSH with QTXEG110SF for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 35 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 85 sq ft with 8-ft ceilings (76 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Broan QTXEG110S = QTXEGSH with QTXEG110SF?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan QTXEG110S = QTXEGSH with QTXEG110SF.
What acoustic sone tier does Broan QTXEG110S = QTXEGSH with QTXEG110SF occupy in EPA filings?
With 0.4 sones at 0.1 in. w.g., Broan QTXEG110S = QTXEGSH with QTXEG110SF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Broan QTXEG110S = QTXEGSH with QTXEG110SF add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan QTXEG110S = QTXEGSH with QTXEG110SF averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan QTXEG110S = QTXEGSH with QTXEG110SF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG110S = QTXEGSH with QTXEG110SF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QTXEG110S = QTXEGSH with QTXEG110SF?
Broan QTXEG110S = QTXEGSH with QTXEG110SF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QTXEG110S = QTXEGSH with QTXEG110SF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG110S = QTXEGSH with QTXEG110SF's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan QTXEG110S = QTXEGSH with QTXEG110SF pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG110S = QTXEGSH with QTXEG110SF easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan QTXEG110S = QTXEGSH with QTXEG110SF in a bathroom remodel?
Avoid specifying Broan QTXEG110S = QTXEGSH with QTXEG110SF in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan QTXEG110S = QTXEGSH with QTXEG110SF airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan QTXEG110S = QTXEGSH with QTXEG110SF achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)