Rated for 110 CFM open-air (85.6 CFM at 0.25 in. w.g.), Broan QTXEG110SX = QTXEGSH with QTXEG110SFX registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 85 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG110SX = QTXEGSH with QTXEG110SFX Exhaust before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 85.6 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 77.8% @ 0.25"
- Motor Draw
- 23.4 W (8.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 85.6 CFM at 0.25 in. w.g. (77.8% retention, 9.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places QTXEG110SX = QTXEGSH with QTXEG110SFX (series: QT SERIES) (PD #4008358) among 207 Broan entries qualified through 2025-02-07. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 23.4 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 205.0 kWh/yr (~$32.80/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (120.0 CFM).
How does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan QTXEG110SX = QTXEGSH with QTXEG110SFX (0.4 sones).
How do flex elbows choke Broan QTXEG110SX = QTXEGSH with QTXEG110SFX at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan QTXEG110SX = QTXEGSH with QTXEG110SFX moving full rated CFM.
Does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX meet residential exhaust fan code specs?
Inspect Broan QTXEG110SX = QTXEGSH with QTXEG110SFX mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QTXEG110SX = QTXEGSH with QTXEG110SFX / QT SERIES | PD ID 4008358 (Qualified 2025-02-07) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (85.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan QTXEG110SX = QTXEGSH with QTXEG110SFX airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan QTXEG110SX = QTXEGSH with QTXEG110SFX tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 76 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.5 kWh/yr (~$1.36/yr) | 23.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 205.0 kWh/yr (~$32.80/yr) | 23.4 W x 8,760 hrs / 1,000 |
Which competing models share Broan QTXEG110SX = QTXEGSH with QTXEG110SFX airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone RN110 | 110 / 91 CFM | 0.4 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Kaze Appliance SEP120 | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| S&P PC110XP | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| Kaze Appliance SEP120 | 100 / 83.8 CFM | 0.5 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| Dayton 5AE70B | 120 / N/A CFM | 0.5 sones (+0.10) | 6.2 CFM/W | 6 x 8 in. rectangular |
How much airflow margin does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX give your bath?
Run a quick local room-volume check for Broan QTXEG110SX = QTXEGSH with QTXEG110SFX by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Broan QTXEG110SX = QTXEGSH with QTXEG110SF?
Match Broan QTXEG110SX = QTXEGSH with QTXEG110SF directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 35 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 85 sq ft with 8-ft ceilings (76 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Broan QTXEG110SX = QTXEGSH with QTXEG110SFX?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan QTXEG110SX = QTXEGSH with QTXEG110SFX.
What bathroom square footage can Broan QTXEG110SX = QTXEGSH with QTXEG110SFX ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG110SX = QTXEGSH with QTXEG110SFX covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan QTXEG110SX = QTXEGSH with QTXEG110SFX.
What happens to Broan QTXEG110SX = QTXEGSH with QTXEG110SFX CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan QTXEG110SX = QTXEGSH with QTXEG110SFX moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX sit on acoustic comfort for senior homeowners?
Measuring 0.4 sones, Broan QTXEG110SX = QTXEGSH with QTXEG110SFX operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Broan QTXEG110SX = QTXEGSH with QTXEG110SFX cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan QTXEG110SX = QTXEGSH with QTXEG110SFX 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan QTXEG110SX = QTXEGSH with QTXEG110SFX pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG110SX = QTXEGSH with QTXEG110SFX's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QTXEG110SX = QTXEGSH with QTXEG110SFX?
Broan QTXEG110SX = QTXEGSH with QTXEG110SFX features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QTXEG110SX = QTXEGSH with QTXEG110SFX's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG110SX = QTXEGSH with QTXEG110SFX's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)