Certified by EPA ENERGY STAR, Nutone RN110 delivers 110 CFM free-air (91 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 3.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 91 sq ft (8-ft height) or 80 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone RN110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 91 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 82.7% @ 0.25"
- Motor Draw
- 29.7 W (10.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nutone RN110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91 CFM at 0.25 in. w.g. (82.7% retention, 5.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Nutone's 16-unit lineup, RN110 (series: Ultra Pro) carries PD #2248883 dating to 2015-10-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 29.7 watts, about 10.8 kWh/yr (~$1.73/yr at $0.16/kWh) for 1 hr/day shower timers or 260.2 kWh/yr (~$41.63/yr) continuously. Closest competing matches include Broan RB110 (110.0 CFM) and Broan QTXEG110 (110.0 CFM).
How noisy is Nutone RN110 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Nutone RN110 measures 0.4 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Nutone RN110 airflow?
Connecting Nutone RN110 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Nutone RN110 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Nutone RN110 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nutone (16 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RN110 / Ultra Pro | PD ID 2248883 (Qualified 2015-10-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (91 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Nutone RN110?
Calculated coverage metrics translate Nutone RN110 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 91 sq ft | 1 CFM/sq ft @ 91 CFM |
| Tall Bath (9-ft Ceiling) | Up to 80 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 41 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.8 kWh/yr (~$1.73/yr) | 29.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 260.2 kWh/yr (~$41.63/yr) | 29.7 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Nutone RN110?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan RB110 | 110 / 91 CFM | 0.4 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Broan QTXEG110 | 110 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110 = QTXEGH with QTXEG110F | 110 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110S | 110 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110S = QTXEGSH with QTXEG110SF | 110 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |
Does Nutone RN110 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Nutone RN110 percentage capacity without sending data.
What plumbing or duct constraints rule out Nutone RN110?
Compare where Nutone RN110 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 41 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 91 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Nutone RN110?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Nutone RN110.
Can Nutone RN110 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Nutone RN110 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Nutone RN110 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Nutone RN110 lacks adequate reserve.
How does Nutone RN110 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Nutone RN110 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Nutone RN110 quiet enough for a primary bedroom bathroom?
At 0.4 sones, Nutone RN110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Nutone RN110 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Nutone RN110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone RN110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nutone RN110?
Nutone RN110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nutone RN110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone RN110's safe coverage footprint from 50 sq ft to 44 sq ft.