Tested under HVI protocols, the Broan QTXEG110S exhaust unit achieves 110 CFM at 0.1 in. w.g. (85.6 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 85 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG110S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 85.6 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 77.8% @ 0.25"
- Motor Draw
- 23.4 W (8.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan QTXEG110S vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 85.6 CFM at 0.25 in. w.g. (77.8% retention, 9.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Broan maintains 207 active ENERGY STAR blowers; QTXEG110S (series: QT SERIES) (PD #3629728) gained qualification on 2024-09-27. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 23.4 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 205.0 kWh/yr (~$32.80/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (120.0 CFM).
Where do Broan QTXEG110S sones rank across EPA ENERGY STAR fans?
Comparing Broan QTXEG110S (0.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan QTXEG110S CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan QTXEG110S, preventing premature peeling paint and mold growth.
How does Broan QTXEG110S measure up on airflow and noise ratings?
Each row below breaks down Broan QTXEG110S certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | QTXEG110S / QT SERIES | PD ID 3629728 (Qualified 2024-09-27) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (85.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan QTXEG110S CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 76 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.5 kWh/yr (~$1.36/yr) | 23.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 205.0 kWh/yr (~$32.80/yr) | 23.4 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan QTXEG110S?
Compare Broan QTXEG110S side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone RN110 | 110 / 91 CFM | 0.4 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Kaze Appliance SEP120 | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| S&P PC110XP | 120 / 94.2 CFM | 0.3 sones (-0.10) | 4.2 CFM/W | 6 in. diameter |
| Kaze Appliance SEP120 | 100 / 83.8 CFM | 0.5 sones (+0.10) | 3.6 CFM/W | 4 in. diameter |
| Dayton 5AE70B | 120 / N/A CFM | 0.5 sones (+0.10) | 6.2 CFM/W | 6 x 8 in. rectangular |
Can you size Broan QTXEG110S for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan QTXEG110S verified capacity.
Which bath layouts should avoid specifying Broan QTXEG110S?
Match Broan QTXEG110S directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 85.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.4 sones up to 85 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan QTXEG110S?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan QTXEG110S.
What happens to Broan QTXEG110S CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan QTXEG110S moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Broan QTXEG110S sit on acoustic comfort for senior homeowners?
Measuring 0.4 sones, Broan QTXEG110S operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Broan QTXEG110S cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan QTXEG110S 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan QTXEG110S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG110S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan QTXEG110S?
Broan QTXEG110S features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan QTXEG110S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG110S's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan QTXEG110S ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG110S covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan QTXEG110S run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan QTXEG110S.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)