Skip to main content
Grant Estimator

Broan QTXEG110SX Exhaust Fan Specifications

ENERGY STAR PD #4008359 · Bathroom/Utility Room · Qualified 2025-02-07
Verified Specification Summary

The Broan QTXEG110SX (QT SERIES) moves 110 CFM at 0.1 in. w.g. (85.6 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones), and delivers 4.7 CFM/W efficacy, sizing bathrooms up to 85 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG110SX Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 85.6 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
77.8% @ 0.25"
Motor Draw
23.4 W (8.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QTXEG110SX vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 85.6 CFM at 0.25 in. w.g. (77.8% retention, 9.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4008359 verifies QTXEG110SX (series: QT SERIES) under Broan (207 listed models, qualified 2025-02-07). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 23.4 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 205.0 kWh/yr (~$32.80/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (120.0 CFM).

Where does Broan QTXEG110SX sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.4 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

How does duct geometry alter Broan QTXEG110SX static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan QTXEG110SX?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan QTXEG110SX alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QTXEG110SX / QT SERIES PD ID 4008359 (Qualified 2025-02-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Broan QTXEG110SX ventilate safely?

Sizing outputs below convert Broan QTXEG110SX tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan QTXEG110SX
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85.6 CFM
Tall Bath (9-ft Ceiling)Up to 76 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.5 kWh/yr (~$1.36/yr)23.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2205.0 kWh/yr (~$32.80/yr)23.4 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan QTXEG110SX closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone RN110 110 / 91 CFM 0.4 sones (Same) 3.7 CFM/W 4 in. diameter
Kaze Appliance SEP120 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
S&P PC110XP 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
Kaze Appliance SEP120 100 / 83.8 CFM 0.5 sones (+0.10) 3.6 CFM/W 4 in. diameter
Dayton 5AE70B 120 / N/A CFM 0.5 sones (+0.10) 6.2 CFM/W 6 x 8 in. rectangular

Will Broan QTXEG110SX clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan QTXEG110SX satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

What plumbing or duct constraints rule out Broan QTXEG110SX?

Compare where Broan QTXEG110SX excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 35 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 85 sq ft with 8-ft ceilings (76 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Broan QTXEG110SX?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan QTXEG110SX.

Why might a contractor swap Broan QTXEG110SX for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan QTXEG110SX lacks adequate reserve.

How does Broan QTXEG110SX handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan QTXEG110SX yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Broan QTXEG110SX quiet enough for a primary bedroom bathroom?

At 0.4 sones, Broan QTXEG110SX operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan QTXEG110SX energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan QTXEG110SX pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG110SX's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QTXEG110SX?

Broan QTXEG110SX features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QTXEG110SX's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG110SX's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan QTXEG110SX serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan QTXEG110SX supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories