Skip to main content
Grant Estimator

S&P PC110XP Exhaust Fan Specifications

ENERGY STAR PD #2402470 · Bathroom/Utility Room · Qualified 2022-09-16
Verified Specification Summary

Tested under HVI protocols, the S&P PC110XP exhaust unit achieves 120 CFM at 0.1 in. w.g. (94.2 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 94 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC110XP Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / 94.2 CFM
Noise @ 0.1"
0.3 sones (#24/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
78.5% @ 0.25"
Motor Draw
28.6 W (10.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PC110XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 120 CFM open-air to 94.2 CFM at 0.25 in. w.g. (78.5% retention, 9.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

S&P maintains 29 active ENERGY STAR blowers; PC110XP (series: PC) (PD #2402470) gained qualification on 2022-09-16. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.6 watts, about 10.4 kWh/yr (~$1.66/yr at $0.16/kWh) for 1 hr/day shower timers or 250.5 kWh/yr (~$40.08/yr) continuously. Closest competing matches include Kaze Appliance SEP120 (120.0 CFM) and Broan QTXEG110 (110.0 CFM).

Where do S&P PC110XP sones rank across EPA ENERGY STAR fans?

Comparing S&P PC110XP (0.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.3 sone: 0.3 sones (8th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.3 sone: 0.3 sones (P8)

What attic duct routing preserves S&P PC110XP CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on S&P PC110XP, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does S&P PC110XP measure up on airflow and noise ratings?

Each row below breaks down S&P PC110XP certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PC110XP / PC PD ID 2402470 (Qualified 2022-09-16)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (94.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect S&P PC110XP CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for S&P PC110XP
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 94 sq ft1 CFM/sq ft @ 94.2 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 44 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.4 kWh/yr (~$1.66/yr)28.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2250.5 kWh/yr (~$40.08/yr)28.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against S&P PC110XP?

Compare S&P PC110XP side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Kaze Appliance SEP120 120 / 94.2 CFM 0.3 sones (Same) 4.2 CFM/W 6 in. diameter
Broan QTXEG110 110 / 85.6 CFM 0.4 sones (+0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110 = QTXEGH with QTXEG110F 110 / 85.6 CFM 0.4 sones (+0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110S 110 / 85.6 CFM 0.4 sones (+0.10) 4.7 CFM/W 6 in. diameter
Broan QTXEG110S = QTXEGSH with QTXEG110SF 110 / 85.6 CFM 0.4 sones (+0.10) 4.7 CFM/W 6 in. diameter

Can you size S&P PC110XP for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P PC110XP verified capacity.

What plumbing or duct constraints rule out S&P PC110XP?

Compare where S&P PC110XP excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 94.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.3 sones up to 94 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to S&P PC110XP?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P PC110XP.

How does S&P PC110XP handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., S&P PC110XP yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is S&P PC110XP quiet enough for a primary bedroom bathroom?

At 0.3 sones, S&P PC110XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is S&P PC110XP energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can S&P PC110XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC110XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PC110XP?

S&P PC110XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PC110XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC110XP's safe coverage footprint from 50 sq ft to 44 sq ft.

Can S&P PC110XP serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: S&P PC110XP supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap S&P PC110XP for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, S&P PC110XP lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories