The Broan (Canada) XB110L1 (ULTRA) moves 110 CFM at 0.1 in. w.g. (110.3 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones), and delivers 12.6 CFM/W efficacy, sizing bathrooms up to 110 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan (Canada) XB110L1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 110.3 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 12.6 CFM/W (#66/1,145)
- Static Retention
- 100.3% @ 0.25"
- Motor Draw
- 8.7 W (3.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan (Canada) XB110L1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.3 CFM out of 110 CFM (100.3% retention, 12.6 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Broan (Canada) registers 3 certified models, with SKU XB110L1 (series: ULTRA) (PD #2305733) certified since 2017-10-27. Lighting kit: Yes. At 12.6 CFM/W (#66 of 1,145, top 6.0% of 1,145 rated models, more efficient than 94.0% of rated models, 7.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.7 watts, about 3.2 kWh/yr (~$0.51/yr at $0.16/kWh) for 1 hr/day shower timers or 76.2 kWh/yr (~$12.19/yr) continuously. Closest competing matches include Broan XB110HL1 (110.0 CFM) and Pennbarry ZQ110 6" (110.0 CFM).
Where does Broan (Canada) XB110L1 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.3 sones against all 1,145 EPA listings.
How does duct geometry alter Broan (Canada) XB110L1 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan (Canada) XB110L1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan (Canada) XB110L1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (Canada) (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | XB110L1 / ULTRA | PD ID 2305733 (Qualified 2017-10-27) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (110.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Broan (Canada) XB110L1 ventilate safely?
Sizing outputs below convert Broan (Canada) XB110L1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.2 kWh/yr (~$0.51/yr) | 8.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 76.2 kWh/yr (~$12.19/yr) | 8.7 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan (Canada) XB110L1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan XB110HL1 | 110 / 110.3 CFM | 0.3 sones (Same) | 12.6 CFM/W | 6 in. diameter |
| Pennbarry ZQ110 6" | 110 / N/A CFM | 0.3 sones (Same) | 13.1 CFM/W | 8 in. diameter |
| Broan XB110 | 110 / 110.2 CFM | 0.3 sones (Same) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110=XB000HwithXB110F | 110 / 110.2 CFM | 0.1 sones (-0.20) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110H | 110 / 110.2 CFM | 0.1 sones (-0.20) | 14.3 CFM/W | 6 in. diameter |
Will Broan (Canada) XB110L1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan (Canada) XB110L1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Broan (Canada) XB110L1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan (Canada) XB110L1.
Limitations & Who Should Skip
- Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 110 sq ft with 8-ft ceilings (98 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Broan (Canada) XB110L1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan (Canada) XB110L1.
Does running Broan (Canada) XB110L1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan (Canada) XB110L1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan (Canada) XB110L1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan (Canada) XB110L1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan (Canada) XB110L1?
Broan (Canada) XB110L1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan (Canada) XB110L1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan (Canada) XB110L1's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan (Canada) XB110L1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan (Canada) XB110L1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan (Canada) XB110L1?
Do not force Broan (Canada) XB110L1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan (Canada) XB110L1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan (Canada) XB110L1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.
Will Broan (Canada) XB110L1 disturb adjacent bedrooms during night use?
Acoustic measurement places Broan (Canada) XB110L1 at 0.3 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)