Broan XB110H Exhaust Fan Specifications

ENERGY STAR PD #2404742 · Bathroom/Utility Room · Qualified 2022-11-18
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan XB110H tests at 110 CFM free discharge (110.2 CFM at 0.25 in. w.g.) and registers #10 of 607 in quietness (0.1 sones) and delivers 14.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 110 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB110H Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 110.2 CFM
Noise @ 0.1"
0.1 sones (#10/607)
Efficacy Rank
14.3 CFM/W (#34/1,145)
Static Retention
100.2% @ 0.25"
Motor Draw
7.7 W (2.8 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan XB110H vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.2 CFM out of 110 CFM (100.2% retention, 12.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Broan XB110H (series: ULTRA GREEN) under PD #2404742 (207 models registered, 2022-11-18). Lighting kit: No. At 14.3 CFM/W (#34 of 1,145, top 3.1% of 1,145 rated models, more efficient than 96.9% of rated models, 9.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.7 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 67.5 kWh/yr (~$10.80/yr) continuously. Closest competing matches include Pennbarry ZQ110 6" (110.0 CFM) and Broan (Canada) XB110L1 (110.0 CFM).

Does Broan XB110H fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan XB110H at 0.1 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.1 sone: 0.1 sones (3rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.1 sone: 0.1 sones (P3)

Why avoid unvented attic termination with Broan XB110H?

Under ASHRAE 62.2 best practice, Broan XB110H needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan XB110H?

Before cutting ceiling drywall or sizing attic transitions for Broan XB110H, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series XB110H / ULTRA GREEN PD ID 2404742 (Qualified 2022-11-18)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan XB110H?

Bathroom ventilation sizing below maps Broan XB110H motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan XB110H
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.2 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.267.5 kWh/yr (~$10.80/yr)7.7 W x 8,760 hrs / 1,000

What peer models sit nearest Broan XB110H in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan XB110H.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Pennbarry ZQ110 6" 110 / N/A CFM 0.3 sones (+0.20) 13.1 CFM/W 8 in. diameter
Broan (Canada) XB110L1 110 / 110.3 CFM 0.3 sones (+0.20) 12.6 CFM/W 6 in. diameter
Broan XB110=XB000HwithXB110F 110 / 110.2 CFM 0.1 sones (Same) 14.3 CFM/W 6 in. diameter
Broan XB110 110 / 110.2 CFM 0.3 sones (+0.20) 14.3 CFM/W 6 in. diameter
Broan XB110HL1 110 / 110.3 CFM 0.3 sones (+0.20) 12.6 CFM/W 6 in. diameter

What percentage of room demand does Broan XB110H cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan XB110H tested delivery.

What plumbing or duct constraints rule out Broan XB110H?

Compare where Broan XB110H excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 110.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.1 sones up to 110 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan XB110H?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan XB110H.

Why might a contractor swap Broan XB110H for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan XB110H lacks adequate reserve.

How does Broan XB110H handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan XB110H yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Broan XB110H quiet enough for a primary bedroom bathroom?

At 0.1 sones, Broan XB110H operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan XB110H energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan XB110H pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB110H's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan XB110H?

Broan XB110H features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan XB110H's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB110H's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan XB110H serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan XB110H supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)