Delta 80HS Exhaust Fan Specifications

ENERGY STAR PD #2395651 · Bathroom/Utility Room · Qualified 2022-05-06
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta 80HS delivers 80 CFM free-air (59 CFM at 0.25 in. w.g.) and registers #18 of 607 in quietness (0.2 sones) and delivers 11.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 59 sq ft (8-ft height) or 52 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta 80HS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 59 CFM
Noise @ 0.1"
0.2 sones (#18/607)
Efficacy Rank
11.4 CFM/W (#115/1,145)
Static Retention
73.8% @ 0.25"
Motor Draw
7.0 W (2.6 kWh/yr)
Duct & Tier
4 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta 80HS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.2 sones (#18 of 607 rated models, quietest 3.8% of 607 rated models, quieter than 96.2% of rated models, 0.80 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59 CFM at 0.25 in. w.g. (73.8% retention, 13.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU 80HS (series: BreezSignature) (PD #2395651) certified since 2022-05-06. Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.0 watts, about 2.6 kWh/yr (~$0.42/yr at $0.16/kWh) for 1 hr/day shower timers or 61.3 kWh/yr (~$9.81/yr) continuously. Closest competing matches include Broan XB80 (80.0 CFM) and Broan XB80=XB00HwithXB80F (80.0 CFM).

How noisy is Delta 80HS compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Delta 80HS measures 0.2 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.2 sone: 0.2 sones (4th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.2 sone: 0.2 sones (P4)

Why does rigid 4 in. diameter ducting protect Delta 80HS airflow?

Connecting Delta 80HS through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta 80HS performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta 80HS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series 80HS / BreezSignature PD ID 2395651 (Qualified 2022-05-06)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (59 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Delta 80HS?

Calculated coverage metrics translate Delta 80HS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta 80HS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 59 sq ft1 CFM/sq ft @ 59 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.6 kWh/yr (~$0.42/yr)7.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.261.3 kWh/yr (~$9.81/yr)7.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta 80HS?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan XB80 80 / 80 CFM 0.3 sones (+0.10) 10.5 CFM/W 4 in. diameter
Broan XB80=XB00HwithXB80F 80 / 80 CFM 0.3 sones (+0.10) 10.5 CFM/W 4 in. diameter
Pennbarry ZQ80-4" 80 / N/A CFM 0.3 sones (+0.10) 10.2 CFM/W 8 in. diameter
Broan XB80 80 / 80 CFM 0.3 sones (+0.10) 13.8 CFM/W 6 in. diameter
Broan XB80=XB00HwithXB80F 80 / 80 CFM 0.1 sones (-0.10) 13.8 CFM/W 6 in. diameter

Does Delta 80HS match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta 80HS percentage capacity without sending data.

When does Delta 80HS fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta 80HS.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 59 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta 80HS?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta 80HS.

Which bathroom layouts should pick a larger blower than Delta 80HS?

Do not force Delta 80HS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Delta 80HS retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta 80HS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Delta 80HS disturb adjacent bedrooms during night use?

Acoustic measurement places Delta 80HS at 0.2 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Delta 80HS continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta 80HS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Delta 80HS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta 80HS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta 80HS?

Delta 80HS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta 80HS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta 80HS's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Delta 80HS code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta 80HS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories