Skip to main content
Grant Estimator

Broan XB80 Exhaust Fan Specifications

ENERGY STAR PD #2248864 · Bathroom/Utility Room · Qualified 2015-10-01
Verified Specification Summary

Tested under HVI protocols, the Broan XB80 exhaust unit achieves 80 CFM at 0.1 in. w.g. (80 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones) and delivers 10.5 CFM/W efficacy, covering standard baths up to 80 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 80 CFM
Noise @ 0.1"
0.3 sones (#24/607)
Efficacy Rank
10.5 CFM/W (#158/1,145)
Static Retention
100.0% @ 0.25"
Motor Draw
7.6 W (2.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan XB80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80 CFM out of 80 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan XB80 (series: Ultra) under PD #2248864 (207 models registered, 2015-10-01). Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Pennbarry ZQ80-4" (80.0 CFM) and Delta SIG80 (80.0 CFM).

Where do Broan XB80 sones rank across EPA ENERGY STAR fans?

Comparing Broan XB80 (0.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.3 sone: 0.3 sones (8th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.3 sone: 0.3 sones (P8)

What attic duct routing preserves Broan XB80 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan XB80, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan XB80 measure up on airflow and noise ratings?

Each row below breaks down Broan XB80 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series XB80 / Ultra PD ID 2248864 (Qualified 2015-10-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (80 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan XB80 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan XB80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 80 sq ft1 CFM/sq ft @ 80 CFM
Tall Bath (9-ft Ceiling)Up to 71 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 30 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.266.6 kWh/yr (~$10.66/yr)7.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan XB80?

Compare Broan XB80 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Pennbarry ZQ80-4" 80 / N/A CFM 0.3 sones (Same) 10.2 CFM/W 8 in. diameter
Delta SIG80 80 / 80.4 CFM 0.3 sones (Same) 9.6 CFM/W 4 in. diameter
Delta 80HS 80 / 59 CFM 0.2 sones (-0.10) 11.4 CFM/W 4 in. diameter
Panasonic RG-S80LHA 80 / 83.9 CFM 0.5 sones (+0.20) 9.3 CFM/W 4 in. diameter
Broan XB80=XB00HwithXB80F 80 / 80 CFM 0.3 sones (Same) 10.5 CFM/W 4 in. diameter

Can you size Broan XB80 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan XB80 verified capacity.

Where should contractors skip Broan XB80 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan XB80 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 80 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.3 sones up to 80 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan XB80?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan XB80.

What duct and room conditions disqualify Broan XB80?

Rule out Broan XB80 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan XB80 capacity?

Because static drag at 0.25 in. w.g. lowers Broan XB80 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan XB80 compared with a standard 3.0 sone builder fan?

Tested at 0.3 sones, Broan XB80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan XB80 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan XB80 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan XB80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan XB80?

Broan XB80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan XB80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB80's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan XB80 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan XB80 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories