Homeowners specifying Broan XB80 gain 80 CFM at 0.1 in. w.g. (80 CFM at 0.25 in. w.g.) where it registers #24 of 607 in quietness (0.3 sones) and delivers 13.8 CFM/W efficacy, venting bathrooms up to 80 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 80 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 13.8 CFM/W (#44/1,145)
- Static Retention
- 100.0% @ 0.25"
- Motor Draw
- 5.8 W (2.1 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan XB80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80 CFM out of 80 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Broan XB80 (series: Ultra) under PD #2248863 (207 models registered, 2015-10-01). Lighting kit: No. At 13.8 CFM/W (#44 of 1,145, top 3.9% of 1,145 rated models, more efficient than 96.1% of rated models, 9.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 5.8 watts, about 2.1 kWh/yr (~$0.34/yr at $0.16/kWh) for 1 hr/day shower timers or 50.8 kWh/yr (~$8.13/yr) continuously. Closest competing matches include DewStop - Breeze Easy BEL80 (80.0 CFM) and DewStop - Breeze Easy BES80 (80.0 CFM).
What acoustic percentile does Broan XB80 occupy among 1,145 bath blowers?
Inspect how Broan XB80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Broan XB80 best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Broan XB80 housings.
Where do Broan XB80 acoustic and static metrics stand?
Compare Broan XB80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | XB80 / Ultra | PD ID 2248863 (Qualified 2015-10-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (80 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Broan XB80 handle taller ceilings or walk-in tub steam?
Evaluate how Broan XB80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 80 sq ft | 1 CFM/sq ft @ 80 CFM |
| Tall Bath (9-ft Ceiling) | Up to 71 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 30 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.1 kWh/yr (~$0.34/yr) | 5.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 50.8 kWh/yr (~$8.13/yr) | 5.8 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Broan XB80?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| DewStop - Breeze Easy BEL80 | 80 / 86.6 CFM | 0.4 sones (+0.10) | 15.7 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BES80 | 80 / 84.9 CFM | 0.3 sones (Same) | 16.1 CFM/W | 4 in. diameter |
| Delta 80HS | 80 / 59 CFM | 0.2 sones (-0.10) | 11.4 CFM/W | 4 in. diameter |
| Revent RVS80 | 80 / 88.8 CFM | 0.6 sones (+0.30) | 12.6 CFM/W | 4 in. diameter |
| Revent RVSH80 | 80 / 88.8 CFM | 0.6 sones (+0.30) | 12.6 CFM/W | 4 in. diameter |
Is Broan XB80 sized right for your shower or tub room?
Check whether Broan XB80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Which bath layouts should avoid specifying Broan XB80?
Match Broan XB80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 30 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 80 CFM net static output
- Optimal use: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Broan XB80?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan XB80.
What happens to Broan XB80 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan XB80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Broan XB80 sit on acoustic comfort for senior homeowners?
Measuring 0.3 sones, Broan XB80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Broan XB80 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan XB80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan XB80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan XB80?
Broan XB80 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan XB80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB80's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan XB80 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan XB80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan XB80 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan XB80.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)