Rated for 80 CFM open-air (83.9 CFM at 0.25 in. w.g.), Panasonic RG-S80LHA registers #83 of 607 in quietness (0.5 sones) and delivers 9.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 83 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic RG-S80LHA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 83.9 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 9.3 CFM/W (#258/1,145)
- Static Retention
- 104.9% @ 0.25"
- Motor Draw
- 8.6 W (3.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic RG-S80LHA vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 83.9 CFM out of 80 CFM (104.9% retention, 17.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Panasonic registers 92 certified models, with SKU RG-S80LHA (series: Whisper Slim) (PD #2669655) certified since 2023-07-21. Lighting kit: Yes. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Delta SIG80 (80.0 CFM) and Pennbarry ZQ80-4" (80.0 CFM).
How does Panasonic RG-S80LHA acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Panasonic RG-S80LHA (0.5 sones).
How do flex elbows choke Panasonic RG-S80LHA at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic RG-S80LHA moving full rated CFM.
Does Panasonic RG-S80LHA meet residential exhaust fan code specs?
Inspect Panasonic RG-S80LHA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RG-S80LHA / Whisper Slim | PD ID 2669655 (Qualified 2023-07-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (83.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Panasonic RG-S80LHA airflow output?
Annual electricity figures and room square-footage ceilings below reflect Panasonic RG-S80LHA tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 83 sq ft | 1 CFM/sq ft @ 83.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 33 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 75.3 kWh/yr (~$12.05/yr) | 8.6 W x 8,760 hrs / 1,000 |
Which competing models share Panasonic RG-S80LHA airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta SIG80 | 80 / 80.4 CFM | 0.3 sones (-0.20) | 9.6 CFM/W | 4 in. diameter |
| Pennbarry ZQ80-4" | 80 / N/A CFM | 0.3 sones (-0.20) | 10.2 CFM/W | 8 in. diameter |
| Broan XB80 | 80 / 80 CFM | 0.3 sones (-0.20) | 10.5 CFM/W | 4 in. diameter |
| Broan XB80=XB00HwithXB80F | 80 / 80 CFM | 0.3 sones (-0.20) | 10.5 CFM/W | 4 in. diameter |
| Delta 80F | 80 / 68.8 CFM | 0.8 sones (+0.30) | 9.5 CFM/W | 4 in. diameter |
How much airflow margin does Panasonic RG-S80LHA give your bath?
Run a quick local room-volume check for Panasonic RG-S80LHA by entering square footage and ceiling height to spot under-vented steam risks early.
Does Panasonic RG-S80LHA suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic RG-S80LHA for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 33 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 83 sq ft with 8-ft ceilings (74 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Panasonic RG-S80LHA?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic RG-S80LHA.
Does Panasonic RG-S80LHA pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic RG-S80LHA easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Panasonic RG-S80LHA in a bathroom remodel?
Avoid specifying Panasonic RG-S80LHA in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Panasonic RG-S80LHA airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic RG-S80LHA achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Panasonic RG-S80LHA occupy in EPA filings?
With 0.5 sones at 0.1 in. w.g., Panasonic RG-S80LHA operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Panasonic RG-S80LHA add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Panasonic RG-S80LHA averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Panasonic RG-S80LHA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic RG-S80LHA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic RG-S80LHA?
Panasonic RG-S80LHA features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic RG-S80LHA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic RG-S80LHA's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)