Utilitech UTS506070 Exhaust Fan Specifications

ENERGY STAR PD #4668474 · Bathroom/Utility Room · Qualified 2026-07-08
Verified Specification Summary

In EPA dataset 8dv7-nngq, Utilitech UTS506070 tests at 70 CFM free discharge (79 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 79 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTS506070 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 79 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.2 CFM/W (#330/1,145)
Static Retention
112.9% @ 0.25"
Motor Draw
8.5 W (3.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Utilitech UTS506070 vs. 1,145-Model ENERGY STAR Benchmarks show?

Utilitech UTS506070 (EPA filing PD #4668474) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79 CFM out of 70 CFM (112.9% retention, 25.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places UTS506070 (series: Utilitech) (PD #4668474) among 22 Utilitech entries qualified through 2026-07-08. Lighting kit: No. At 8.2 CFM/W (#330 of 1,145, top 29.4% of 1,145 rated models, more efficient than 70.6% of rated models, 3.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.5 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 74.5 kWh/yr (~$11.92/yr) continuously. Closest competing matches include Delta VFB080B4A1-LVDC (80.0 CFM) and Delta 80F-LED (80.0 CFM).

Why avoid unvented attic termination with Utilitech UTS506070?

Under ASHRAE 62.2 best practice, Utilitech UTS506070 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Utilitech UTS506070?

Before cutting ceiling drywall or sizing attic transitions for Utilitech UTS506070, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Utilitech (22 models) ENERGY STAR Certified Partner
Model Number & Series UTS506070 / Utilitech PD ID 4668474 (Qualified 2026-07-08)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (79 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Utilitech UTS506070?

Bathroom ventilation sizing below maps Utilitech UTS506070 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Utilitech UTS506070
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 79 sq ft1 CFM/sq ft @ 79 CFM
Tall Bath (9-ft Ceiling)Up to 70 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 29 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.1 kWh/yr (~$0.50/yr)8.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.274.5 kWh/yr (~$11.92/yr)8.5 W x 8,760 hrs / 1,000

What peer models sit nearest Utilitech UTS506070 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Utilitech UTS506070.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VFB080B4A1-LVDC 80 / 61.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta 80F-LED 80 / 61.5 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-BN 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-MB 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter

What percentage of room demand does Utilitech UTS506070 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Utilitech UTS506070 tested delivery.

Who should not install Utilitech UTS506070 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Utilitech UTS506070 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 79 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around ENERGY STAR sones up to 79 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Utilitech UTS506070?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Utilitech UTS506070.

Does Utilitech UTS506070 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Utilitech UTS506070 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Utilitech UTS506070 undersized or poorly matched for a bath renovation?

Skip Utilitech UTS506070 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Utilitech UTS506070 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Utilitech UTS506070 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Utilitech UTS506070 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Utilitech UTS506070 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Utilitech UTS506070?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Utilitech UTS506070 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTS506070's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Utilitech UTS506070?

Utilitech UTS506070 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Utilitech UTS506070's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTS506070's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)